A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Implementation and Challenges of International Atomic Energy Agency/American Association of Physicists in Medicine TRS 483 Formalism for Field Output Factors and Involved Uncertainties Determination in Small Fields for TomoTherapy. | LitMetric

Purpose: International Atomic Energy Agency published TRS-483 to address the issues of small field dosimetry. Our study calculates the output factor in the small fields of TomoTherapy using different detectors and dosimetric conditions. Furthermore, it estimates the various components of uncertainty and presents challenges faced during implementation.

Materials And Methods: Beam quality TPR(10) at the hypothetical field size of 10 cm × 10 cm was calculated from TPR(S). Two ionization chambers based on the minimum field width required to satisfy the lateral charge particle equilibrium and one unshielded electron field diode (EFD) were selected. Output factor measurements were performed in various dosimetric conditions.

Results: Beam quality TPR(10) has a mean value of 0.627 ± 0.001. The maximum variation of output factor between CC01 chamber and EFD diode at the smallest field size was 11.80%. In source to surface setup, the difference between water and virtual water was up to 9.68% and 8.13%, respectively, for the CC01 chamber and EFD diode. The total uncertainty in the ionization chamber was 2.43 times higher compared to the unshielded EFD diode at the smallest field size.

Conclusions: Beam quality measurements, chamber selection procedure, and output factors were successfully carried out. A difference of up to 10% in output factor can occur if density scaling for electron density in virtual water is not considered. The uncertainty in output correction factors dominates, while positional and meter reading uncertainty makes a minor contribution to total uncertainty. An unshielded EFD diode is a preferred detector in small fields because of lower uncertainty in measurements compared to ionization chambers.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8491308PMC
http://dx.doi.org/10.4103/jmp.JMP_11_21DOI Listing

Publication Analysis

Top Keywords

output factor
16
efd diode
16
small fields
12
beam quality
12
international atomic
8
atomic energy
8
output factors
8
fields tomotherapy
8
quality tpr10
8
field size
8