Reliable, easy-to-use, and cost-effective wearable sensors are desirable for continuous measurements of flexions and torsions of the trunk, in order to assess risks and prevent injuries related to body movements in various contexts. Piezo-capacitive stretch sensors, made of dielectric elastomer membranes coated with compliant electrodes, have recently been described as a wearable, lightweight and low-cost technology to monitor body kinematics. An increase of their capacitance upon stretching can be used to sense angular movements. Here, we report on a wearable wireless system that, using two sensing stripes arranged on shoulder straps, can detect flexions and torsions of the trunk, following a simple and fast calibration with a conventional tri-axial gyroscope on board. The piezo-capacitive sensors avoid the errors that would be introduced by continuous sensing with a gyroscope, due to its typical drift. Relative to stereophotogrammetry (non-wearable standard system for motion capture), pure flexions and pure torsions could be detected by the piezo-capacitive sensors with a root mean square error of ~8° and ~12°, respectively, whilst for flexion and torsion components in compound movements, the error was ~13° and ~15°, respectively.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8539866PMC
http://dx.doi.org/10.3390/s21206706DOI Listing

Publication Analysis

Top Keywords

flexions torsions
12
torsions trunk
12
wearable sensors
8
piezo-capacitive sensors
8
sensors
5
monitoring flexions
4
torsions
4
trunk gyroscope-calibrated
4
gyroscope-calibrated capacitive
4
capacitive elastomeric
4

Similar Publications

Traditional methods for evaluating tennis technique, such as visual observation and video analysis, are often subjective and time consuming. On the other hand, a quick and accurate assessment can provide immediate feedback to players and contribute to technical development, particularly in less experienced athletes. This study aims to validate the use of a single inertial measurement system to assess some relevant technical parameters of amateur players.

View Article and Find Full Text PDF

Development and biomechanical evaluation of a 3D printed analogue of the human lumbar spine.

3D Print Med

January 2025

Musculoskeletal Biomechanics Research Lab, Department of Mechanical Engineering, McGill University, 845 Sherbrooke St. W (163), Montréal, QC, H3A 0C3, Canada.

Background: There exists a need for validated lumbar spine models in spine biomechanics research. Although cadaveric testing is the current gold standard for spinal implant development, it poses significant issues related to reliability and repeatability due to the wide variability in cadaveric physiologies. Moreover, there are increasing ethical concerns with human dissection practices.

View Article and Find Full Text PDF

Purpose: To propose a new sign of patellar maltracking in recurrent patellar dislocation (RPD) and compare the differences in lower limb rotational and bony structural abnormalities among the different signs.

Patients And Methods: A retrospective study included 279 patients (mean age: 22 years; female: 81%) who underwent primary surgery for RPD over the past 4 years was performed. The patients were grouped based on the characteristics of patellar tracking: low-, moderate- and high-grade J-sign.

View Article and Find Full Text PDF

Introduction: This study aimed to evaluate the mechanical properties of Reciproc, Reciproc Blue, One RECI, and R-Motion, specifically focusing on their flexibility and buckling resistance and to assess their torsional fatigue behavior under 2 different reciprocation angles (150°/30° or 70°/30°).

Methods: A total of 160 instruments (40 per brand) were tested. Flexion and buckling tests were conducted using a Universal testing machine (DL 200 MF).

View Article and Find Full Text PDF

Background: Lumbar degenerative diseases are an important factor in disability worldwide, and they are also common among the elderly population. Stand-Alone Oblique Lumbar Interbody Fusion (Stand-Alone OLIF) is a novel surgical approach for treating lumbar degenerative diseases. However, long-term follow-up after surgery has revealed the risk of endplate collapse associated with Stand-Alone OLIF procedures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!