Anisotropic elastic behavior of a hydrogel-coated electrospun polyurethane: Suitability for heart valve leaflets.

J Mech Behav Biomed Mater

James T. Willerson Center for Cardiovascular Modeling and Simulation, The Oden Institute for Computational Engineering and Sciences, USA; Department of Mechanical Engineering, The University of Texas at Austin, Austin, TX, USA; Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, USA. Electronic address:

Published: January 2022

Although xenograft biomaterials have been used for decades in replacement heart valves, they continue to face multiple limitations, including limited durability, mineralization, and restricted design space due to their biological origins. These issues necessitate the need for novel replacement heart valve biomaterials that are durable, non-thrombogenic, and compatible with transcatheter aortic valve replacement devices. In this study, we explored the suitability of an electrospun poly(carbonate urethane) (ES-PCU) mesh coated with a poly(ethylene glycol) diacrylate (PEGDA) hydrogel as a synthetic biomaterial for replacement heart valve leaflets. In this material design, the mesh provides the mechanical support, while the hydrogel provides the required surface hemocompatibility. We conducted a comprehensive study to characterize the structural and mechanical properties of the uncoated mesh as well as the hydrogel-coated mesh (composite biomaterial) over the estimated operational range. We found that the composite biomaterial was functionally robust with reproducible stress-strain behavior within and beyond the functional ranges for replacement heart valves, and was able to withstand the rigors of mechanical evaluation without any observable damage. In addition, the composite biomaterial displayed a wide range of mechanical anisotropic responses, which were governed by fiber orientation of the mesh, which in turn, was controlled with the fabrication process. Finally, we developed a novel constitutive modeling approach to predict the mechanical behavior of the composite biomaterial under in-plane extension and shear deformation modes. This model identified the existence of fiber-fiber mechanical interactions in the mesh that have not previously been reported. Interestingly, there was no evidence of fiber-hydrogel mechanical interactions. This important finding suggests that the hydrogel coating can be optimized for hemocompatibility independent of the structural mechanical responses required by the leaflet. This initial study indicated that the composite biomaterial has mechanical properties well-suited for replacement heart valve applications and that the electrospun mesh microarchitecture and hydrogel biological properties can be optimized independently. It also reveals that the structural mechanisms contributing to the mechanical response are more complicated than what was previously established and paves the pathway for more detailed future studies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8818123PMC
http://dx.doi.org/10.1016/j.jmbbm.2021.104877DOI Listing

Publication Analysis

Top Keywords

replacement heart
20
composite biomaterial
20
heart valve
16
mechanical
10
valve leaflets
8
heart valves
8
structural mechanical
8
mechanical properties
8
mechanical interactions
8
mesh
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!