Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: Retinal displacement is common following rhegmatogenous retinal detachment (RRD) repair. A computer simulation was developed to assess forces applied by a gas tamponade of various sizes in the setting of pneumatic retinopexy (PnR) versus pars plana vitrectomy (PPV).
Design: Computer simulation model.
Methods: The contact angle and pressure between the tamponade and the retina were calculated using interfacial tension and the densities of gas and vitreous. A simulation determined the dynamics of fluid motion in the subretinal space and calculated deformations of the retina.
Results: Bulk flow of fluid away from the tamponade in a direction along gravity stretched the retina and caused displacement in the simulations. Extent of displacement is attributable to the subretinal fluid layer thickness, and area of contact and contact pressure applied by the tamponade. Larger gas tamponades have greater contact pressure applied to the retina. Reducing gas bubble size from 93% to 6.25% with PPV versus PnR, there was a 79% reduction in the mean contact pressure (1.4 mmHg-0.29 mmHg), and a 93% reduction in the surface area of contact (11 cm -0.8 cm ). Therefore, the contact force applied to the entire retina decreases by 97% from 83 mN (PPV) to 2.9 mN (PnR). The model resembling PnR had more than three times less displacement compared to PPV.
Conclusions: This model provides a framework to study retinal displacement. Our findings suggest that proportional to their size, gas tamponades stretched the retina by displacing subretinal fluid following RRD repair.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/aos.15050 | DOI Listing |