Until now, the over-exploitation of wild resources has increased growing concern over the quality of wild medicinal plants. This led to the necessity of developing a rapid method for the evaluation of wild medicinal plants. In this study, the content of total secoiridoids (gentiopicroside, swertiamarin, and sweroside) of from 37 different regions in southwest China were analyzed by high performance liquid chromatography (HPLC). Furthermore, Fourier transform infrared (FT-IR) was adopted to trace the geographical origin (331 individuals) and predict the content of total secoiridoids (273 individuals). In the traditional FT-IR analysis, only one scatter correction technique could be selected from a series of preprocessing candidates to decrease the impact of the light correcting effect. Nevertheless, different scatter correction techniques may carry complementary information so that using the single scatter correction technique is sub-optimal. Hence, the emerging ensemble approach to preprocessing fusion, sequential preprocessing through orthogonalization (SPORT), was carried out to fuse the complementary information linked to different preprocessing methods. The results suggested that, compared with the best results obtained on the scatter correction modeling, SPORT increased the accuracy of the test set by 12.8% in qualitative analysis and decreased the RMSEP by 66.7% in quantitative analysis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8531481PMC
http://dx.doi.org/10.3389/fpls.2021.759248DOI Listing

Publication Analysis

Top Keywords

scatter correction
16
wild medicinal
12
medicinal plants
12
content total
8
total secoiridoids
8
correction technique
8
novel multi-preprocessing
4
multi-preprocessing integration
4
integration method
4
method qualitative
4

Similar Publications

Biomarkers.

Alzheimers Dement

December 2024

Austin Health, Melbourne, VIC, Australia.

Background: New generation PET scanners achieve superior resolution and sensitivity, but the implications on beta amyloid (Aβ) quantitation are not well understood. The Centiloid (CL) scale (Klunk et al., 2015) was introduced to promote consistent Aβ burden quantification across different positron emission tomography (PET) tracers and quantification pipelines, but was not intended to control for hardware or reconstruction changes.

View Article and Find Full Text PDF

Background: The Maintain Your Brain (MYB) randomised controlled trial (RCT) examined the effect of a multi-domain internet-based dementia prevention program against a control group (information only) over three years among Australians aged 55-77 years. A cost-effective analysis (CEA) quantified the differences in costs (direct healthcare and program costs) and effectiveness outcomes between the intervention and control groups from a health care sector perspective.

Method: An economic evaluation was conducted alongside the MYB trial.

View Article and Find Full Text PDF

Purpose: To compare the clinical outcomes, surgical workflow, and patient satisfaction following small incision lenticule extraction (SMILE) performed with the VisuMax 800 in one eye and the VisuMax 500 in the contralateral eye (both Carl Zeiss Meditec).

Methods: This was a prospective, single-site clinical study of patients undergoing SMILE for myopia and myopic astigmatism between February 2022 and August 2023. Each patient underwent bilateral treatment using the VisuMax 800 (VM800 group) in one eye and the VisuMax 500 (VM500 group) in the contralateral eye.

View Article and Find Full Text PDF

Scleral Contact Lens Benefits for Myopic Patients With Regular Corneas: A Prospective Randomized Study.

Eye Contact Lens

November 2024

Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China.

Objectives: To evaluate the impact of scleral contact lens (SL) wear on the visual quality and the ocular surface wettability in myopic patients with regular corneas.

Methods: This prospective, randomized, controlled study enrolled a total of 80 myopes with regular corneas. Subjects were randomly allocated to wear SL or rigid corneal lens (RCL) for 3 months.

View Article and Find Full Text PDF

Rapid and accurate detection of protein content is essential for ensuring the quality of maize. Near-infrared spectroscopy (NIR) technology faces limitations due to surface effects and sample homogeneity issues when measuring the protein content of whole maize grains. Focusing on maize grain powder can significantly improve the quality of data and the accuracy of model predictions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!