Magnetic Resonance Imaging (MRI) has become part of the clinical routine for diagnosing neurodegenerative disorders. Since acquisitions are performed at multiple centers using multiple imaging systems, detailed analysis of brain volumetry differences between MRI systems and scan-rescan acquisitions can provide valuable information to correct for different MRI scanner effects in multi-center longitudinal studies. To this end, five healthy controls and five patients belonging to various stages of the AD continuum underwent brain MRI acquisitions on three different MRI systems (Philips Achieva dStream 1.5T, Philips Ingenia 3T, and GE Discovery MR750w 3T) with harmonized scan parameters. Each participant underwent two subsequent MRI scans per imaging system, repeated on three different MRI systems within 2 h. Brain volumes computed by icobrain dm (v5.0) were analyzed using absolute and percentual volume differences, Dice similarity (DSC) and intraclass correlation coefficients, and coefficients of variation (CV). Harmonized scans obtained with different scanners of the same manufacturer had a measurement error closer to the intra-scanner performance. The gap between intra- and inter-scanner comparisons grew when comparing scans from different manufacturers. This was observed at image level (image contrast, similarity, and geometry) and translated into a higher variability of automated brain volumetry. Mixed effects modeling revealed a significant effect of scanner type on some brain volumes, and of the scanner combination on DSC. The study concluded a good intra- and inter-scanner reproducibility, as illustrated by an average intra-scanner (inter-scanner) CV below 2% (5%) and an excellent overlap of brain structure segmentation (mean DSC > 0.88).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8530224PMC
http://dx.doi.org/10.3389/fnagi.2021.746982DOI Listing

Publication Analysis

Top Keywords

brain volumetry
12
mri systems
12
variability automated
8
automated brain
8
magnetic resonance
8
resonance imaging
8
imaging systems
8
three mri
8
brain volumes
8
intra- inter-scanner
8

Similar Publications

Background: Cognitive Reserve(CR) a concept based on the brain plasticity, is a mechanism that delays or minimizes clinical manifestations of brain changes due to aging. Prospective epidemiologic studies non-demented individuals have shown that education, occupational duration and complexity, and greater lifetime engagement in cognitively stimulating activities are associated with a reduced risk of dementia. We study the cognitive reserve and its neuroimaging correlate.

View Article and Find Full Text PDF

Background: Early detection is crucial for alleviating Alzheimer's disease (AD) burden. At present, assessment for early detection of AD is time-consuming, costly, and often invasive. In recent years, various eye-tracking methodologies have emerged, and they show promising results in detecting persons at risk of developing AD dementia (ADD).

View Article and Find Full Text PDF

Objectives: Distinguishing dementia with Lewy bodies (DLB) from Alzheimer's disease (AD) dementia, particularly in patients with DLB and concomitant AD pathology (DLB/AD+), can be challenging and there is no specific MRI signature for DLB. The aim of this study is to examine the additional value of MRI-based brain volumetry in separating patients with DLB (AD+/-) from patients with AD and controls.

Methods: We included 1518 participants from four cohorts (ADC, ADNI, PDBP and PredictND); 147 were patients with DLB (n = 76, DLB/AD+; n = 71, DLB/AD-), 668 patients with AD dementia, and 703 controls.

View Article and Find Full Text PDF

Age-related atrophy of the human hippocampus and the enthorinal cortex starts accelerating at around age 60. Due to the contributions of these regions to many cognitive functions seamlessly used in everyday life, this can heavily impact the lives of elderly people. The hippocampus is not a unitary structure, and mechanisms of its age-related decline appear to differentially affect its subfields.

View Article and Find Full Text PDF

Background And Purpose: The magnetic resonance images (MRIs) ability of lesion detection in epilepsy is crucial for a diagnosis and surgical outcome. Using automated artificial intelligence (AI)-based tools for measuring cortical thickness and brain volume originally developed for dementia, we aimed to identify whether it could lateralize epilepsy with normal MRIs.

Methods: Non-lesional 3-Tesla MRIs of 428 patients diagnosed with focal epilepsy, based on semiology and electroencephalography findings, were analyzed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?