Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: To design and assess a novel penile fracture simulation model for teaching penile fracture repair.
Methods: We used a validated circumcision simulator to create a model. Foreskin for a circumcision was divided into two halves. A transverse slit ("simulated fracture") was created on one part of the first half of the foreskin (mimicking "tunica") and was applied over the penile model. A red jelly tablet ("clot") was placed underneath the cut. A second full-length of foreskin was applied over it to cover the defect. The model was assessed by participants and expert faculty at the Urology Simulation Boot Camp. Evaluation was performed using a 5-point Likert Scale questionnaire. Data was analysed using Microsoft Excel and IBM SPSS Statistics V25. The intra-class correlation was calculated using a "One-way random model".
Results: Twenty-two urology trainees and four experts participated in the evaluation. The majority of trainees strongly agreed (59%, n = 13) the model is useful for training with experts similarly agreeing in 75% of cases. The appearance of penile fracture was considered good by both trainees (68%, n = 14) and faculty (75%). Overall, the ability of the model to represent a realistic simulation of the task was considered excellent by 23% of participants and good by 64%. Personal confidence after simulation in managing a similar situation was considered high among trainees. The main difficulties reported were related to fascial planes and urethra.
Conclusion: This is the first simulation model for penile fracture repair and has demonstrated face validity at a national urology bootcamp.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.acuroe.2020.10.014 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!