Cost-Effectiveness of Flash Glucose Monitoring for the Management of Patients with Type 1 and Patients with Type 2 Diabetes in China.

Diabetes Ther

National Health Commission Key Laboratory of Health Technology Assessment, School of Public Health, Fudan University, Shanghai, China.

Published: December 2021

Introduction: To compare the cost-effectiveness of flash glucose monitoring versus self-monitoring of blood glucose/point of care testing (SMBG/POCT) in both patients with type 1 and patients with type 2 diabetes (T1D/T2D) receiving insulin therapy.

Methods: The IQVIA CORE Diabetes Model (version 9.5) was used to project the lifetime costs and health outcomes of flash glucose monitoring and SMBG/POCT from a Chinese societal perspective. We considered both hospital and individual version flash glucose monitoring to reflect the clinical practice in China. The clinical inputs leveraged the outcomes from both clinical trials and real-world studies. Cohort characteristics, intervention costs, treatment-related disutility and mortality were extracted from the literature. We also conducted scenario analyses and probabilistic sensitivity analyses to test the robustness of results.

Results: Compared with SMBG/POCT using efficacy results from clinical trial, flash glucose monitoring brought the incremental costs of Chinese yuan (CNY) 58,021 and CNY 90,997 and additional quality-adjusted life years (QALYs) of 1.22 and 0.65 for patients with T1D and patients with T2D, respectively. According to the "WHO-CHOICE threshold" of three times the gross domestic product per capita in China (CNY 217,341 in 2020) as cost-effectiveness threshold, flash glucose monitoring was cost-effective for both patients with T1D and patients with T2D with incremental cost-effectiveness ratios (ICER) of CNY 47,636 and CNY 140,297 per QALY gained, respectively. According to the real-world effectiveness data, flash glucose monitoring was dominant for patients with T1D (lower costs and better effectiveness) and cost-effective for patients with T2D with an ICER of CNY 124,169 per QALY gained compared with SMBG/POCT. Scenario analyses and probabilistic sensitivity analyses confirmed the robustness of the results.

Conclusion: Flash glucose monitoring is likely to be considered as a cost-effective strategy compared to SMBG/POCT for Chinese patients with T1D and patients with T2D receiving insulin therapy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8586326PMC
http://dx.doi.org/10.1007/s13300-021-01166-zDOI Listing

Publication Analysis

Top Keywords

flash glucose
32
glucose monitoring
32
patients t1d
16
patients t2d
16
patients
12
compared smbg/poct
12
t1d patients
12
cost-effectiveness flash
8
glucose
8
monitoring
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!