Significance: This investigation examines the effectiveness of several common contact lens solutions in the disinfection of Acanthamoeba, which causes a serious eye infection most often resulting from dysfunctional or improper use of contact lens products.
Purpose: Acanthamoeba keratitis is an eye infection caused by a free-living amoeba, which can lead to extensive corneal damage and frequently blindness. Acanthamoeba keratitis is linked with contact lens use combined with noncompliance with contact lens care cleaning regimens. The patient's choice and use of multipurpose solutions (MPSs) continue to be a risk factor for Acanthamoeba keratitis. Thus, it is critical that the Acanthamoeba disinfection efficacy of the popular MPSs be determined. Here we compare the efficacy of seven major MPSs on the global market.
Methods: Using standard methods of Acanthamoeba disinfection and quantification, Acanthamoeba ATCC 30461, 30868, 50370, and 50676 trophozoites were inoculated into each MPS and held for the manufacturer's recommended disinfection time. Acanthamoeba recovery plates were incubated for 14 days, after which positive wells were identified and cell concentrations determined using the 50% endpoint method.
Results: Members of the OPTI-FREE products (Express, Replenish, and Puremoist [Alcon, Fort Worth, TX]) demonstrated significantly higher percentages of antimicrobial activity compared with the renu Advanced Formula (Bausch + Lomb, Rochester, NY), Biotrue (Bausch + Lomb), Acuvue RevitaLens (Johnson & Johnson, Santa Ana, CA), and Lite products (Cooper Vision, Scottsville, NY) for four of the trophozoite strains tested.
Conclusions: Many of the popular MPS biocides maintain little or no antimicrobial activity against Acanthamoeba trophozoites, and the number of biocides in an MPS does not necessarily indicate its antimicrobial activity.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8677607 | PMC |
http://dx.doi.org/10.1097/OPX.0000000000001819 | DOI Listing |
Purpose: This study compares and evaluates the parameters of iridotrabecular contact (ITC) in patients with primary angle closure disease (PACD) with natural lenses and pseudophakia based on anterior segment imaging data from swept-source optical coherence tomography (SS-OCT).
Material And Methods: This retrospective study analyzed data from 92 patients aged 32 to 89 years, and included 56 patients with PACD (43 with natural lenses and 13 with pseudophakia) and 36 in the control group (21 with natural lenses and 15 with pseudophakia). All participants underwent SS-OCT (CASIA2; Tomey Corporation, Japan), which included an assessment of the ITC Index and ITC Area.
In this Prentice Medal Award lecture, I shall recount my career in vision science in the context of three types of inspiration-"being inspired," "personal inspiration," and "inspiring others." My research has derived inspiration from a variety of sources, such as contemporary and historical research doyens in the ophthalmic field and beyond, artists, Greek philosophers, and abstract constructs such as principles and adages. A given moment of inspiration can range from being a profound experience to a subtle realization during a quiet moment of reflection.
View Article and Find Full Text PDFIndian J Ophthalmol
December 2024
University Eye Clinic Maastricht, Maastricht University Medical Center, Maastricht, The Netherlands.
Purpose: To study change in the contact of intraocular lens (IOL) with the posterior capsule with respect to the vertical versus horizontal orientation of the haptic-optic junction of the IOL using intraoperative spectral domain optical coherence tomography (SD-OCT).
Methods: Fifty eyes of 50 patients with senile immature cataract underwent topical phacoemulsification procedure with implantation of a monofocal IOL by a single experienced surgeon. The Rescan 700 SD-OCT system was used for intraoperative imaging.
Cureus
November 2024
Ophthalmology, International University of Health and Welfare, Chiba, JPN.
Keratoconus is a condition that causes progressive thinning and anterior protrusion of the cornea. Because of its irregular astigmatism, mild to moderate keratoconus is corrected with hard contact lenses (HCLs), but blepharoptosis due to the long-term wearing of HCLs is often a problem. In this study, we investigated blepharoptosis in HCL wearers with keratoconus.
View Article and Find Full Text PDFCont Lens Anterior Eye
December 2024
Optometry and Vision Science, Queensland University of Technology, Kelvin Grove, Queensland, Australia. Electronic address:
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!