  • - The study examined the effects of artificial toothbrushing on six types of 3D printed resins and CAD/CAM materials, focusing on surface roughness, waviness, Vickers hardness, and color changes.
  • - Formlabs denture teeth A2 resin (FMLB) showed no significant change in surface roughness or waviness after brushing, while other materials like PMMA demonstrated notable increases in waviness.
  • - The Vickers hardness of FMLB and NextDent C&B (NXT) remained unaffected, and their mechanical properties were comparable to traditional CAD/CAM materials, indicating stability even after toothbrushing.

Article Abstract

This study analyzed the surface roughness and waviness, Vickers hardness (VHN), and color changes of six types of 3D printed resins and computer-aided design/computer-aided manufacturing (CAD/CAM) materials after artificial toothbrushing. The average surface roughness height (Ra) change of Formlabs denture teeth A2 resin (FMLB) was not significant between after artificial toothbrushing (0.17 ± 0.02 μm and 0.17 ± 0.05 μm, respectively; mean ± standard deviation). However, the Ra value increased significantly in all remaining groups. Regarding waviness, polymethylmethacrylate (PMMA) had the largest increases in average waviness height (Wa) and maximum surface waviness height (Wz) between, before (0.43 ± 0.23 μm and 0.08 ± 0.02 μm), and after (8.67 ± 4.03 μm, 1.30 ± 0.58 μm) toothbrushing. There were no significant changes in Wa for Formlabs denture teeth A2 resin (FMLB) and NextDent C&B (NXT). After artificial toothbrushing, the dispersed-filler composite (DFC) group had the largest color difference (ΔE, of 2.4 ± 0.9), and the remaining materials had smaller changes than the clinical acceptance threshold of ΔE = 2.25. The VHN of FMLB and NXT were 9.1 ± 0.4 and 15.5 ± 0.4, respectively, and were not affected by artificial toothbrushing. The flexural strengths of the 3D printed materials were 139.4 ± 40.5 MPa and 163.9 ± 14.0 MPa for FMLB and NXT, respectively, which were similar to those of the polycarbonate and PMMA groups (155.2 ± 23.6 MPa and 108.0 ± 8.1 MPa, respectively). This study found that the evaluated 3D printed materials had mechanical and optical properties comparable to those of CAD/CAM materials and were stable even after artificial toothbrushing and hydrothermal aging.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8540203PMC
http://dx.doi.org/10.3390/ma14206207DOI Listing

Publication Analysis

Top Keywords

artificial toothbrushing
20
cad/cam materials
12
hydrothermal aging
8
surface roughness
8
formlabs denture
8
denture teeth
8
teeth resin
8
resin fmlb
8
002 μm
8
waviness height
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!