A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Load-Bearing Capacity of Beams Reinforced with Composite Rebar in Regard to Existing Guidelines. | LitMetric

Load-Bearing Capacity of Beams Reinforced with Composite Rebar in Regard to Existing Guidelines.

Materials (Basel)

Faculty of Civil and Environmental Engineering, West Pomeranian University of Technology, Szczecin, al. Piastow 50a, 71-311 Szczecin, Poland.

Published: October 2021

Non-metallic reinforcement such as fiber-reinforced polymer (FRP) is now being increasingly used in construction. Despite numerous similarities, elements reinforced with non-metallic bars work differently from the ones reinforced with steel bars, including cracking and failure mode. The examination of the stress state in these elements, so important for their proper design, raises many difficulties. The article presents the results of tests of bended beams reinforced with GFRP bars. The results of the experimental tests were compared with calculations based on selected design instructions. The results have shown that beams reinforced with GFRP exhibit increased cracking, higher deflection, and often mode of failure through crushing of concrete. The results have shown that in bended elements reinforced with the GFRP bars, the rebar often does not achieve the strength declared by the manufacturer. The study has shown that theoretical values of load-bearing capacity of beams reinforced with composite rebar differ greatly between different guidelines and instruction. The analysis showed that the use of GFRP bars as a replacement for steel bars is possible in demanding environmental conditions. However, excessive deflections and cracks may result in limited application due to overall serviceability requirements of the element.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8541087PMC
http://dx.doi.org/10.3390/ma14206116DOI Listing

Publication Analysis

Top Keywords

beams reinforced
16
reinforced gfrp
12
gfrp bars
12
load-bearing capacity
8
capacity beams
8
reinforced composite
8
composite rebar
8
elements reinforced
8
steel bars
8
reinforced
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!