(1) Background: Chest radiography (CXR) is still a key diagnostic component in the emergency department (ED). Correct interpretation is essential since some pathologies require urgent treatment. This study quantifies potential discrepancies in CXR analysis between radiologists and non-radiology physicians in training with ED experience. (2) Methods: Nine differently qualified physicians (three board-certified radiologists [BCR], three radiology residents [RR], and three non-radiology residents involved in ED [NRR]) evaluated a series of 563 posterior-anterior CXR images by quantifying suspicion for four relevant pathologies: pleural effusion, pneumothorax, pneumonia, and pulmonary nodules. Reading results were noted separately for each hemithorax on a Likert scale (0-4; 0: no suspicion of pathology, 4: safe existence of pathology) adding up to a total of 40,536 reported pathology suspicions. Interrater reliability/correlation and Kruskal-Wallis tests were performed for statistical analysis. (3) Results: While interrater reliability was good among radiologists, major discrepancies between radiologists' and non-radiologists' reading results could be observed in all pathologies. Highest overall interrater agreement was found for pneumothorax detection and lowest agreement in raising suspicion for malignancy suspicious nodules. Pleural effusion and pneumonia were often suspected with indifferent choices (1-3). In terms of pneumothorax detection, all readers mainly decided for a clear option (0 or 4). Interrater reliability was usually higher when evaluating the right hemithorax (all pathologies except pneumothorax). (4) Conclusions: Quantified CXR interrater reliability analysis displays a general uncertainty and strongly depends on medical training. NRR can benefit from radiology reporting in terms of time efficiency and diagnostic accuracy. CXR evaluation of long-time trained ED specialists has not been tested.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8534346PMC
http://dx.doi.org/10.3390/diagnostics11101868DOI Listing

Publication Analysis

Top Keywords

interrater reliability
12
emergency department
8
pleural effusion
8
pneumothorax detection
8
cxr
5
interrater
5
interpretation thoracic
4
thoracic radiography
4
radiography large
4
large discrepancies
4

Similar Publications

Bullet characterization using Photon-Counting detector CT: A phantom study with intact bullets.

Eur J Radiol

December 2024

Department of Radiology and Nuclear Medicine, Maastricht University Medical Centre+, PO Box 5800, 6202 AZ Maastricht, the Netherlands; Mental Health and Sciences (MHeNs) Research Institute, Maastricht University, PO Box 616, 6200 MD Maastricht, the Netherlands.

Objectives: Photon-counting detector CT (PCD-CT) is expected to substantially improve and expand CT-imaging applicability due to its intrinsic spectral capabilities, increased spatial resolution, reduced electronic noise, and improved image contrast. The current study aim is to evaluate PCD-CT efficacy in characterizing bullets based on their dimensions, shape, and material composition.

Materials And Methods: This is an observational phantom study examining 11 unfired, intact bullets of various common calibers, placed in ballistic gelatin.

View Article and Find Full Text PDF

Background: Despite the increasing integration of competency-based education in medicine, there remains a significant gap in effectively assessing educational outcomes, underscoring the urgent need for designed assessment blueprints that accurately reflect both curriculum content and competency standards in Community Medicine for undergraduate students. This study, conducted across the All-India Institute of Medical Sciences (AIIMS) network, develops a summative assessment blueprint aimed at standardizing evaluations in medical education across diverse geographic locations in India.

Methods: Twenty-five experts from 10 All India Institutes of Medical Science were invited via email and contributed for summative assessment for a theory paper.

View Article and Find Full Text PDF

Human imagination has garnered growing interest in many fields. However, it remains unclear how to characterize different forms of imaginative thinking and how imagination differs between young and older adults. Here, we introduce a novel scoring protocol based on recent theoretical developments in the cognitive neuroscience of imagination to provide a broad tool with which to characterize imaginative thinking.

View Article and Find Full Text PDF

Objective: Periventricular anastomosis (PA), a recently recognized cause of hemorrhage in moyamoya disease, is reducible after bypass surgery. The timing of the reduction, however, remains poorly understood. The objectives of the present study were to demonstrate radiological reduction of PA occurring within 48 hours after surgery and to identify factors associated with reduction.

View Article and Find Full Text PDF

Background: To intraindividually compare the diagnostic performance of positron emission computed tomography (F-18-FDG-PET/CT) and diffusion-weighted magnetic resonance imaging (DW-MRI) in a non-inferiority design for the discrimination of peripheral nerve sheath tumours as benign (BPNST), atypical (ANF), or malignant (MPNST) in patients with neurofibromatosis type 1 (NF1).

Results: In this prospective single-centre study, thirty-four NF1 patients (18 male; 30 ± 11 years) underwent F-18-FDG-PET/CT and multi-b-value DW-MRI (11 b-values 0 - 800 s/mm²) at 3T. Sixty-six lesions corresponding to 39 BPNST, 11 ANF, and 16 MPNST were evaluated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!