A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Using Transfer Learning Method to Develop an Artificial Intelligence Assisted Triaging for Endotracheal Tube Position on Chest X-ray. | LitMetric

Using Transfer Learning Method to Develop an Artificial Intelligence Assisted Triaging for Endotracheal Tube Position on Chest X-ray.

Diagnostics (Basel)

Professional Master Program in Artificial Intelligence in Medicine, College of Medicine, Taipei Medical University, Taipei 10675, Taiwan.

Published: October 2021

Endotracheal tubes (ETTs) provide a vital connection between the ventilator and patient; however, improper placement can hinder ventilation efficiency or injure the patient. Chest X-ray (CXR) is the most common approach to confirming ETT placement; however, technicians require considerable expertise in the interpretation of CXRs, and formal reports are often delayed. In this study, we developed an artificial intelligence-based triage system to enable the automated assessment of ETT placement in CXRs. Three intensivists performed a review of 4293 CXRs obtained from 2568 ICU patients. The CXRs were labeled "CORRECT" or "INCORRECT" in accordance with ETT placement. A region of interest (ROI) was also cropped out, including the bilateral head of the clavicle, the carina, and the tip of the ETT. Transfer learning was used to train four pre-trained models (VGG16, INCEPTION_V3, RESNET, and DENSENET169) and two models developed in the current study (VGG16_Tensor Projection Layer and CNN_Tensor Projection Layer) with the aim of differentiating the placement of ETTs. Only VGG16 based on ROI images presented acceptable performance (AUROC = 92%, F1 score = 0.87). The results obtained in this study demonstrate the feasibility of using the transfer learning method in the development of AI models by which to assess the placement of ETTs in CXRs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8534985PMC
http://dx.doi.org/10.3390/diagnostics11101844DOI Listing

Publication Analysis

Top Keywords

transfer learning
12
ett placement
12
learning method
8
chest x-ray
8
projection layer
8
placement etts
8
placement
6
cxrs
5
method develop
4
develop artificial
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!