A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Alginate Bead Biosystem for the Determination of Lactate in Sweat Using Image Analysis. | LitMetric

Alginate Bead Biosystem for the Determination of Lactate in Sweat Using Image Analysis.

Biosensors (Basel)

Microfluidics Cluster UPV/EHU, Analytical Microsystems & Materials for Lab-on-a-Chip (AMMa-LOAC) Group, Analytical Chemistry Department, University of the Basque Country UPV/EHU, 48049 Leioa, Spain.

Published: October 2021

Lactate is present in sweat at high concentrations, being a metabolite of high interest in sport science and medicine. Therefore, the potential to determine lactate concentrations in physiological fluids, at the point of need with minimal invasiveness, is very valuable. In this work, the synthesis and performance of an alginate bead biosystem was investigated. Artificial sweat with different lactate concentrations was used as a proof of concept. The lactate detection was based on a colorimetric assay and an image analysis method using lactate oxidase, horseradish peroxidase and tetramethyl benzidine as the reaction mix. Lactate in artificial sweat was detected with a R² = 0.9907 in a linear range from 10 mM to 100 mM, with a limit of detection of 6.4 mM and a limit of quantification of 21.2 mM. Real sweat samples were used as a proof of concept to test the performance of the biosystem, obtaining a lactate concentration of 48 ± 3 mM. This novel sensing configuration, using alginate beads, gives a fast and reliable method for lactate sensing, which could be integrated into more complex analytical systems.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8534122PMC
http://dx.doi.org/10.3390/bios11100379DOI Listing

Publication Analysis

Top Keywords

lactate
9
alginate bead
8
bead biosystem
8
lactate sweat
8
image analysis
8
lactate concentrations
8
artificial sweat
8
proof concept
8
method lactate
8
sweat
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!