A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Safety and durability of cavo-tricuspid isthmus linear ablation in the current era: Single-center 9-year experience from 1078 procedures. | LitMetric

Cavo-tricuspid isthmus (CTI) linear ablation is performed not only for atrial flutter (AFL) but empirically during atrial fibrillation (AF) ablation in real-world practice.  PURPOSE: We sought to evaluate the safety and durability of the CTI ablation.  METHODS: This retrospective study included 1078 consecutive patients who underwent a CTI ablation. AFL was documented before or during the procedure in 249 (23.1%) patients, and an empirical CTI and AF ablation were performed in 829 (76.9%) patients.  RESULTS: CTI block was successfully created in 1051 (97.5%) patients with a 10.3 ± 6.6 min total radiofrequency time. Repeat procedures were performed for recurrent arrhythmias in 187 (17.3%) patients at a median of 11.0 (5.0-30.0) months postprocedure, and conduction resumption was identified in 68/174 (39.1%). Among those undergoing a CTI ablation with an AF ablation, the durability was significantly higher in those with than without documented AFL (78.1% vs. 58.2%, p = .031).  The total radiofrequency time was significantly shorter (9.0 ± 5.3 vs. 10.0 ± 6.4 [mins], p = .024) and durability significantly higher (78.1 vs. 58.7[%], p = .043) in the large-tip than irrigated-tip catheter group. Iatrogenic AFL was observed after the empiric CTI ablation in 11 (1.3%) patients. Procedure-related complications occurred in 15 (1.4%) patients. Eight patients experienced coronary artery spasms, including one with ventricular fibrillation following ST elevation on the ward. The other six patients experienced transient atrioventricular block and one experienced cardiac tamponade requiring drainage.  CONCLUSIONS: Despite a high acute CTI ablation success, the conduction block durability was relatively low after the empiric ablation. An empiric CTI ablation at the time of the AF ablation is not recommended.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jce.15281DOI Listing

Publication Analysis

Top Keywords

cti ablation
24
ablation
12
cti
9
safety durability
8
cavo-tricuspid isthmus
8
linear ablation
8
ablation performed
8
patients
8
total radiofrequency
8
radiofrequency time
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!