Risks to collateral structures exist with radiofrequency (RF) ablation of the left atrium to obtain pulmonary vein isolation (PVI) for the treatment of atrial fibrillation. Passive luminal esophageal temperature (LET) monitoring is commonly utilized, but increasing data suggest limited benefits with LET monitoring. In contrast, active cooling of the esophagus has been shown to significantly reduce esophageal injury. Active cooling of the esophagus also avoids the need for stopping and repositioning an LET probe during use, which may reduce the need for fluoroscopy use. This study aimed to measure the impact on fluoroscopy use during RF ablation with esophageal cooling using a dedicated cooling device in a low-fluoroscopy practice. All patients who underwent PVI over a one-year timeframe by a single provider were analyzed. Patients undergoing PVI prior to the incorporation of an esophageal cooling protocol into standard ablation practice were treated with traditional LET monitoring. Patients treated after this point received active esophageal cooling, in which no LET monitoring is utilized. A total of 280 patients were treated; 91 patients were treated using LET monitoring, and 189 patients were treated with esophageal cooling. The mean total fluoroscopy time before the implementation of the esophageal cooling protocol in 91 patients was 194 seconds [standard deviation (SD): 182 seconds] per case, with a median of 144 seconds. The mean total fluoroscopy time after implementation in 189 patients was 126 seconds (SD: 120 seconds) per case with a median of 96 seconds, representing a reduction of 35% per case (p < 0.0001, Mann-Whitney U test). In this largest study to date of active esophageal cooling during PVI, a 35% reduction in fluoroscopy time compared with patients who received LET monitoring was found. This reduction was seen despite an already low fluoroscopy usage rate in place.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8519316PMC
http://dx.doi.org/10.19102/icrm.2021.121101DOI Listing

Publication Analysis

Top Keywords

esophageal cooling
28
patients treated
16
active esophageal
12
fluoroscopy time
12
cooling
10
esophageal
9
patients
9
fluoroscopy usage
8
active cooling
8
cooling esophagus
8

Similar Publications

: To compare tracheal temperature (T) with nasopharyngeal temperature (T) in patients undergoing cardiac surgery using cardiopulmonary bypass (CPB). : T was measured using a thermistor in the cuff of an endotracheal tube and T was monitored using an esophageal stethoscope. Depending on the management of the CPB strategy, the operation was divided into four periods (pre-CPB, cooling, rewarming, and post-CPB).

View Article and Find Full Text PDF

Introduction: Proactive esophageal cooling reduces injury during radiofrequency (RF) ablation of the left atrium (LA) for the treatment of atrial fibrillation (AF). New catheters are capable of higher wattage settings up to 90 W (very high-power short duration, vHPSD) for 4 s. Varying power and duration, however, does not eliminate the risk of thermal injury.

View Article and Find Full Text PDF

Maintenance of normothermia in the out-of-hospital setting: A pilot comparative crossover study of a foil blanket versus self-warming blanket.

Australas Emerg Care

December 2024

Ambulance Victoria, Doncaster, Victoria, Australia; Monash University, Department of Paramedicine, Frankston, Victoria, Australia; Monash University, School of Public Health and Preventive Medicine, Melbourne, Victoria, Australia. Electronic address:

Introduction: Hypothermia can increase mortality in certain patients. Paramedics apply cotton and foil "space" blankets for warming, yet their effectiveness remains uncertain. This pilot study aimed to evaluate combining cotton blankets with a self-warming blanket versus a combination of cotton blankets and a foil blanket in an out-of-hospital simulation.

View Article and Find Full Text PDF
Article Synopsis
  • Primary atopic disorders (PAD) are rare genetic conditions caused by specific gene variants that affect skin and immune function, making diagnosis challenging among common allergic disease cases.
  • Identifying PAD requires recognizing clinical red flags like family history and unusual infections, as conventional lab tests are inadequate for definitive diagnosis.
  • Whole-genome sequencing (WGS) enhances diagnostic efficiency and accuracy, but requires careful interpretation and collaboration among specialists to effectively manage PAD cases.
View Article and Find Full Text PDF

Inhibiting the expression of spindle appendix cooled coil protein 1 (SPDL1) can slow down disease progression and is related to poor prognosis in patients with esophageal cancer. However, the specific roles and molecular mechanisms of SPDL1 in esophageal squamous cell carcinoma (ESCC) have not been explored yet. The current study aimed to investigate the expression levels of SPDL1 in ESCC via transcriptome analysis using data from The Cancer Genome Atlas (TCGA) and Gene Expression Omnibus databases.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!