Stabilization for displaced dorsoulnar fragments in distal radius fractures is challenging to treat with conventional volar locking plates alone. The integrated compression screw combined with a volar locking plate has been introduced as an additional tool to stabilize the dorsoulnar fragment and has been reported to work effectively. However, the compression screw is unable to stabilize a comminuted dorsal ulnar fragment; therefore, it is necessary to consider using an additional dorsal plate. We have developed a modified surgical technique to stabilize a comminuted dorsal intra-articular fragment by combining the integrated compression screw with a mini-plate as a washer or a buttress.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhsa.2021.09.002DOI Listing

Publication Analysis

Top Keywords

compression screw
16
comminuted dorsal
12
integrated compression
12
dorsal ulnar
8
ulnar fragment
8
distal radius
8
radius fractures
8
screw mini-plate
8
volar locking
8
stabilize comminuted
8

Similar Publications

Finite element investigation for improving chest wall reconstruction process using ceramic and polymeric implants.

Sci Rep

January 2025

Biomedical Engineering Department, Faculty of Engineering, Helwan University, Cairo, Egypt.

Car accidents, infections caused by bacteria or viruses, metastatic lesions, tumors, and malignancies are the most frequent causes of chest wall damage, leading to the removal of the affected area. After excision, artificial bone or synthetic materials are used in chest wall reconstruction to restore the skeletal structure of the chest. Chest implants have traditionally been made from metallic materials like titanium alloys due to their biocompatibility and durability.

View Article and Find Full Text PDF

Background: Severe metaphyseal comminution and sizable bone defect of the distal femur are high risks of fixation failure. To date, no exact magnitude of comminution and bone loss is determined as an indication for augmentation of fixation construct. The present study aimed to investigate the influence of metaphyseal gap width, working length, and screw distribution on the stability of the fixation construct.

View Article and Find Full Text PDF

[Outcomes of Retrograde Femoral Nail Osteosynthesis of Intraarticular Fractures of the Distal Femur].

Acta Chir Orthop Traumatol Cech

January 2025

Klinika ortopedie a traumatologie pohybového ústrojí Fakultní nemocnice Plzeň.

Purpose Of The Study: Intraarticular fractures of the distal femur rank among the most severe musculoskeletal injuries. Various treatment options, such as plate osteosynthesis or retrograde nailing, can be employed. This study aims to evaluate the clinical outcomes and complications of intraarticular distal femoral fractures treated with retrograde femoral nail, with particular emphasis on C3 fractures.

View Article and Find Full Text PDF

Background: The Latarjet and other bony augmentation procedures are commonly used to treat anterior shoulder instability in the setting of significant glenoid bone loss. Although several fixation strategies have been reported, the biomechanical strength of these techniques remains poorly understood.

Purpose: To perform a systematic review of the biomechanical strength of glenoid bony augmentation procedures for anterior shoulder instability.

View Article and Find Full Text PDF

In this work, twin-screw extruder and compression moulding techniques were utilized to fabricate polymer blends: polypropylene (PP), polybutadiene (PB), and composites using glass fibre (GF) and flax fibre (FF). During fabrication, the polymer ratios maintained between PP and PB were 90:10, 80:20, and 70:30. Likewise, the composites were fabricated by varying the ratios between the PP, PB, and GF, which were 90PP:10PB:10GF, 80PP:20PB:10GF, and 70PP:30PB:10GF.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!