Long short-term memory (LSTM) recurrent neural network for muscle activity detection.

J Neuroeng Rehabil

Department of Electronics and Telecommunications, Politecnico Di Torino, 10129, Turin, Italy.

Published: October 2021

Background: The accurate temporal analysis of muscle activation is of great interest in many research areas, spanning from neurorobotic systems to the assessment of altered locomotion patterns in orthopedic and neurological patients and the monitoring of their motor rehabilitation. The performance of the existing muscle activity detectors is strongly affected by both the SNR of the surface electromyography (sEMG) signals and the set of features used to detect the activation intervals. This work aims at introducing and validating a powerful approach to detect muscle activation intervals from sEMG signals, based on long short-term memory (LSTM) recurrent neural networks.

Methods: First, the applicability of the proposed LSTM-based muscle activity detector (LSTM-MAD) is studied through simulated sEMG signals, comparing the LSTM-MAD performance against other two widely used approaches, i.e., the standard approach based on Teager-Kaiser Energy Operator (TKEO) and the traditional approach, used in clinical gait analysis, based on a double-threshold statistical detector (Stat). Second, the effect of the Signal-to-Noise Ratio (SNR) on the performance of the LSTM-MAD is assessed considering simulated signals with nine different SNR values. Finally, the newly introduced approach is validated on real sEMG signals, acquired during both physiological and pathological gait. Electromyography recordings from a total of 20 subjects (8 healthy individuals, 6 orthopedic patients, and 6 neurological patients) were included in the analysis.

Results: The proposed algorithm overcomes the main limitations of the other tested approaches and it works directly on sEMG signals, without the need for background-noise and SNR estimation (as in Stat). Results demonstrate that LSTM-MAD outperforms the other approaches, revealing higher values of F1-score (F1-score > 0.91) and Jaccard similarity index (Jaccard > 0.85), and lower values of onset/offset bias (average absolute bias < 6 ms), both on simulated and real sEMG signals. Moreover, the advantages of using the LSTM-MAD algorithm are particularly evident for signals featuring a low to medium SNR.

Conclusions: The presented approach LSTM-MAD revealed excellent performances against TKEO and Stat. The validation carried out both on simulated and real signals, considering normal as well as pathological motor function during locomotion, demonstrated that it can be considered a powerful tool in the accurate and effective recognition/distinction of muscle activity from background noise in sEMG signals.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8532313PMC
http://dx.doi.org/10.1186/s12984-021-00945-wDOI Listing

Publication Analysis

Top Keywords

semg signals
20
muscle activity
12
long short-term
8
short-term memory
8
memory lstm
8
lstm recurrent
8
recurrent neural
8
muscle activation
8
neurological patients
8
activation intervals
8

Similar Publications

Age-related changes to the orbicularis oculi muscle include impaired eyelid function, such as lagophthalmos, alterations in tear film dynamics, and aesthetic changes like wrinkles, festoons, and the descent of soft tissue. To date, the structural and functional changes that would comprehensively increase our understanding of orbicularis aging have not been analyzed. This study aims to investigate functional outcomes using surface electromyography and correlate them with ultrastructural changes in orbicularis during aging.

View Article and Find Full Text PDF

This study aimed to predict and fit the nonlinear dynamic grip force of the human upper limb using surface electromyographic (sEMG) signals. The research employed a time-series-based neural network, NARX, to establish a mapping relationship between the electromyographic signals of the forearm muscle groups and dynamic grip force. Three-channel electromyographic signal acquisition equipment and a grip force sensor were used to record muscle signals and grip force data of the subjects under specific dynamic force conditions.

View Article and Find Full Text PDF

Detection, identification and removing of artifacts from sEMG signals: Current studies and future challenges.

Comput Biol Med

January 2025

Laboratory of Metrology and Information Processing, Physics Department, Faculty of Sciences, Ibn Zohr University, Agadir, Morocco.

Surface electromyography (sEMG), a non-invasive technique, offers the ability to identify insights into the activities of muscles in the form of electrical pulses. During the process of recording, the sEMG signals frequently become contaminated by a multitude of different artifacts, the origin of which may be attributed to numerous sources. These artifacts affect the reliability and accuracy of the pure sEMG activity, and subsequently reduce the quality of analysis and interpretation.

View Article and Find Full Text PDF

Effectiveness of Using a Digital Wearable Plantar Pressure Device to Detect Muscle Fatigue: Within-Subject, Repeated Measures Experimental Design.

JMIR Hum Factors

January 2025

Department of Biomedical Engineering, Chung Yuan Christian University, No. 200, Zhongbei Road, Zhongli District, Toayuan City, 32023, Taiwan, 886 32564507.

Background: Muscle fatigue, characterized by reduced force generation during repetitive contractions, impacts older adults doing daily activities and athletes during sports activities. While various sensors detect muscle fatigue via muscle activity, biochemical markers, and kinematic parameters, a real-time wearable solution with high usability remains limited. Plantar pressure monitoring detects muscle fatigue through foot loading changes, seamlessly integrating into footwear to improve the usability and compliance for home-based monitoring.

View Article and Find Full Text PDF

This study examined the effects of core and muscle temperature on force steadiness and motor unit discharge rate (MUDR) variability after a hot-water immersion session. Fifteen participants (6 women; 25±6 years) completed neuromuscular assessments before and after either 42ºC (hot) or 36ºC (control) water immersion. Force steadiness was measured during knee extension, while HD-sEMG signals were recorded from vastus lateralis and medialis for MUDR variability analysis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!