Background: Bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction (BASILICA) and laceration of the anterior mitral leaflet to prevent outflow obstruction (LAMPOON) reduce the risk of coronary and left ventricular outflow obstruction obstruction during transcatheter aortic valve replacement and transcatheter mitral valve replacement. Despite successful laceration, BASILICA or LAMPOON may fail to prevent obstruction caused by inadequate leaflet splay in patients having challenging anatomy such as very small valve-to-coronary distance, diffusely calcified, rigid leaflets, or undergoing transcatheter aortic valve replacement inside existing transcatheter aortic valve replacement. We describe a novel technique of balloon-augmented (BA) leaflet laceration to enhance leaflet splay.

Methods: We measured the incremental leaflet splay from BA-BASILICA in vitro. From November 2019 to March 2021, 16 patients underwent BA-BASILICA and 4 BA-LAMPOON at 3 centers.

Results: BA-BASILICA increased benchtop leaflet tip splay 17%, maximum splay angle 30%, and splay area 23%, resulting in a more rounded apex and larger effective area. Sixteen patients at risk for inadequate BASILICA leaflet splay, including 4 transcatheter aortic valve replacement inside existing transcatheter aortic valve replacement, underwent BA-BASILICA. All had successful leaflet laceration. One had coronary obstruction requiring immediate orthotopic stenting. Two underwent elective orthotopic coronary stenting through the transcatheter valve cells for leaflet prolapse without coronary ischemia. There were no deaths during the procedure or at 30 days. Four patients at risk for inadequate anterior mitral leaflet splay underwent BA-LAMPOON. All had successful target leaflet laceration without left ventricular outflow obstruction obstruction or procedural death. One died within 30 days.

Conclusions: BA leaflet laceration enhances leaflet splay in vitro and may allow transcatheter aortic valve replacement and transcatheter mitral valve replacement in patients otherwise ineligible for traditional BASILICA or LAMPOON due to challenging anatomy. Graphic Abstract: A graphic abstract is available for this article.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8673414PMC
http://dx.doi.org/10.1161/CIRCINTERVENTIONS.121.011028DOI Listing

Publication Analysis

Top Keywords

valve replacement
32
transcatheter aortic
24
aortic valve
24
leaflet splay
24
outflow obstruction
16
leaflet laceration
16
leaflet
14
anterior mitral
12
mitral leaflet
12
obstruction
10

Similar Publications

Background: Since the transcatheter valve-in-valve (ViV) procedure was introduced in 2007, a few cases of infective endocarditis (IE) following the ViV procedure have been reported, which can be predisposed by older age, pre-existing medical conditions, and procedural techniques. Paravalvular abscesses constitute a rare complication of IE, resulting from extending IE beyond the valve annulus, less commonly caused by species. This complication is more common in prosthetic valves, particularly bioprosthetic valves.

View Article and Find Full Text PDF

Objective: Aortic valve repair/sparing have been established as effective treatments for aortic regurgitation and/or aortic aneurysms. However, concerns remain regarding long-term durability, reproducibility, and patient selection. This study aims to asses long-term clinical and echocardiographic outcomes, with a focus on aortic regurgitation grade and left ventricular ejection fraction evolution, in adults undergoing these procedures.

View Article and Find Full Text PDF

Background: Transcatheter valve-in-valve replacement (TMViVR) is an alternative option for patients with bioprosthetic valve failure (BVF) who are at high surgical risk. Although infective endocarditis (IE) after transcatheter mitral valve-in-valve replacement is unusual, it is associated with significantly high mortality.

Case Presentation: An 81-year-old male patient was admitted with intermittent thoracic tightness, chest pain persisting for 3 years, and shortness of breath with nausea for 1 week.

View Article and Find Full Text PDF

Long term outcome after surgical tetralogy of Fallot repair at young age: Longitudinal follow-up up to 50 years after surgery.

Int J Cardiol

January 2025

Department of Cardiology, Cardiovascular Institute, Thorax Center, Erasmus MC, Rotterdam, the Netherlands; European Reference Network for Rare, Low Prevalence and Complex Diseases of the Heart (ERN GUARD-Heart), Amsterdam, the Netherlands.

Background: Little is known about the very long-term outcome in Tetralogy of Fallot (ToF) patients.

Objectives: To prospectively evaluate clinical outcome and quality-of-life after surgical repair of ToF.

Methods: Single-centre, longitudinal cohort-study evaluating every decade 144 ToF patients who underwent surgical repair <15 years of age between 1968 and 1980.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!