Purpose: To test the accuracy and reproducibility of a software prototype for semi-automated computer-aided volumetry (CAV) of part-solid pulmonary nodules (PSN) with separate segmentation of the solid part.

Materials And Methods: 66 PSNs were retrospectively identified in 34 thin-slice unenhanced chest CTs of 19 patients. CAV was performed by two medical students. Manual volumetry (MV) was carried out by two radiology residents. The reference standard was determined by an experienced radiologist in consensus with one of the residents. Visual assessment of CAV accuracy was performed. Measurement variability between CAV/MV and the reference standard as a measure of accuracy, CAV inter- and intra-rater variability as well as CAV intrascan variability between two recontruction kernels was determined via the Bland-Altman method and intraclass correlation coefficients (ICC).

Results: Subjectively assessed accuracy of CAV/MV was 77 %/79 %-80 % for the solid part and 67 %/73 %-76 % for the entire nodule. Measurement variability between CAV and the reference standard ranged from -151-117 % for the solid part and -106-54 % for the entire nodule. Interrater variability was -16-16 % for the solid part (ICC 0.998) and -102-65 % for the entire nodule (ICC 0.880). Intra-rater variability was -70-49 % for the solid part (ICC 0.992) and -111-31 % for the entire nodule (ICC 0.929). Intrascan variability between the smooth and the sharp reconstruction kernel was -45-39 % for the solid part and -21-46 % for the entire nodule.

Conclusion: Although the software prototype delivered satisfactory results when segmentation is evaluated subjectively, quantitative statistical analysis revealed room for improvement especially regarding the segmentation accuracy of the solid part and the reproducibility of measurements of the nodule's subsolid margins.

Key Points: · Assessed visually CAV delivers similar accuracy compared to manual volumetry. · Accuracy of CAV was higher for the entire nodule. · Reproducibility was better for the solid part. · Variability between the kernels was higher for the solid part.

Download full-text PDF

Source
http://dx.doi.org/10.1055/a-1656-9834DOI Listing

Publication Analysis

Top Keywords

entire nodule
20
reference standard
12
solid
9
software prototype
8
cav
8
manual volumetry
8
variability
8
measurement variability
8
accuracy cav
8
intra-rater variability
8

Similar Publications

Introduction: Melanoma arising in blue nevus (BN) is usually evident on histopathology. However, there are cases in the gray zone where neither morphology nor immunostains and molecular studies are conclusive.

Case Report: A 33-year-old man presented with greenish discoloration of the abdominal skin at birth.

View Article and Find Full Text PDF

Introduction: Until now, the thyroid cancer case number has increased, and it is not entirely possible to attribute this continuous growth to more meticulous thyroid nodule selection and more accurate diagnostic techniques. While there is currently no conclusive evidence linking dietary factors to thyroid cancer, certain dietary patterns seem to have an impact on the development of the disease. There are interesting connections among diet, environment, metabolism and thyroid carcinogenesis; a deeper comprehension of the underlying mechanisms should help the identification of modifiable risk factors for thyroid cancer.

View Article and Find Full Text PDF

Previous research has demonstrated that postural stability may be improved by increasing stimulation to the somatosensory system. Wearing lower limb compression garments or textured in-soles have been found to be effective short-term methods for improving postural stability, hypothesized to be due to enhanced tactile feedback. The aim of this study was to assess whether a combined compression-tactile sock increases postural stability in healthy adults, compared to barefoot.

View Article and Find Full Text PDF

Lymphatic plastic bronchitis: a study based on CT and MR lymphangiography.

BMC Med Imaging

December 2024

Department of Radiology, Beijing Shijitan Hospital, Capital Medical University, Yangfangdian Tieyiyuan Road No.10, Haidian District, Beijing, 100038, China.

Objectives: To investigate the diagnostic value of CT lymphangiography (CTL) and non-contrast MR lymphangiography (MRL) in lymphatic plastic bronchitis.

Materials And Methods: The clinical and imaging data of 31 patients with lymphatic plastic bronchitis diagnosed by clinical, imaging and pathological results were retrospectively analyzed. All patients underwent CTL and MRL.

View Article and Find Full Text PDF

Background: Therapeutic options for mild hidradenitis suppurativa (HS) represent a significant gap in the current treatment landscape, with no FDA approved therapies for early stage HS. Topical JAnus Kinase inhibitors (JAKi) are a compelling option due to the known upregulation of inflammatory JAK signaling in HS lesions and the recent success of systemic JAKi for moderate to severe HS.

Objectives: This is a pilot, single-site, open-label, prospective 24-week clinical trial with topical ruxolitinib (NCT04414514).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!