A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

2D-shear wave elastography: number of acquisitions can be reduced according to clinical setting. | LitMetric

Background: The factors affecting intra-operator variability of two-dimensional shear wave elastography (2D-SWE) have not been clearly established. We evaluated 2D-SWE variability according to the number of measurements, clinical and laboratory features, and liver stiffness measurements (LSM).

Methods: At least three LSM were performed in 452 patients who underwent LSM by 2D-SWE (supersonic shear imaging) out of an initial database of 1650 patients. The mean value of the three LSM was our best measurement method. Bland-Altman plots were used to evaluate intra-operator variability when considering only one, or the first two measurements. Variability was assessed by taking the absolute value of the difference between the first LSM and the mean of the three LSM. Logistic regression was used to assess the factors associated with the highest tertile of variability.

Results: The limit of agreement was narrower with the mean of the first and second measurements than with each measurement taken separately (- 2.83 to 2.99 kPa vs. - 5.86 to 6.21 kPa and - 5.77 to 5.73 kPa for the first and second measurement, respectively). A BMI ≥ 25 kg/m and a first LSM by 2D-SWE ≥ 7.1 kPa increased the odds of higher variability by 3.4 and 3.9, respectively. Adding a second LSM didn't change the variability in patients with BMI < 25 and a first LSM by 2D-SWE < 7.1 kPa.

Conclusions: Intra-operator variability of LSM by 2D-SWE increases with both a high BMI and high LSM value. In patients with BMI < 25 kg/m and a first LSM < 7.1 kPa we recommend performing only one LSM.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8531167PMC
http://dx.doi.org/10.1186/s13244-021-01090-7DOI Listing

Publication Analysis

Top Keywords

three lsm
12
wave elastography
8
intra-operator variability
8
lsm
7
variability
6
2d-shear wave
4
elastography number
4
number acquisitions
4
acquisitions reduced
4
reduced clinical
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!