A new methodology to determine directly the fungicide boscalid (BSC) was developed and successfully applied in red grape 100% juice, peel extracts, pulp and purple grape seeds ( L.) with a working carbon paste electrode (CPE) without sample preparation. Cyclic voltammetry (CV) indicated the presence of an irreversible cathodic process of BSC at -1.21 V Ag|AgCl (KCl 3.0 mol L) in a solution of 0.100 mol L HCl/acetone 70 : 30 (v/v). This behavior was also observed using Square Wave Voltammetry (SWV). The Differential Pulse Voltammetry (DPV) technique proved to be more sensitive and with higher selectivity for BSC quantification. The influence of pH on the reduction of BSC was investigated in Britton-Robinson Buffer (BRB), 0.01 mol L (pH 2.00-12.00). The limit of detection (LOD) values obtained from calibration curves for different samples were as follows: 0.107 mg L for deionized water; 0.146 mg L for red grape 100% juice; 0.922 mg kg for peel extracts; 0.818 mg kg for grape pulp and 0.691 mg kg for grape seeds. The corresponding Limit of Quantification (LOQ) values for the same samples were as follows: 0.358 mg L; 0.486 mg L; 2.87 mg kg; 2.73 mg kg and 2.51 mg kg, respectively. In addition, the recovery rates for the different concentration levels in the investigated range varied between 97.13 and 103.4%. All tests performed with the samples did not require extraction or pre-concentration steps of BSC, resulting in a fast, simple and cheap methodology.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d1ay01134kDOI Listing

Publication Analysis

Top Keywords

differential pulse
8
pulse voltammetry
8
carbon paste
8
paste electrode
8
red grape
8
grape 100%
8
100% juice
8
peel extracts
8
grape seeds
8
grape
6

Similar Publications

A solution to address the issues of environmental light interference in Remote Photoplethysmography (rPPG) methods is proposed in this paper. First, signals from the face's region of interest (ROI) and background noise signals are simultaneously collected, and the two signals are processed by a differential to obtain a more accurate rPPG signal. This method effectively suppresses background noise and enhances signal quality.

View Article and Find Full Text PDF

This paper summarizes the main findings of a study which aimed to examine the electrochemical oxidation of homovanillic acid (HVA), the final metabolite of dopamine. A pencil graphite electrode (PGE) was used as working electrode and the measurements were performed by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The type and the composition of the graphite leads used as PGE, the pH of the supporting electrolyte, as well as the scan rates were optimized by CV.

View Article and Find Full Text PDF

Deep eutectic solvents (DES) have emerged as versatile, sustainable media for the synthesis of nanomaterials due to their low toxicity, tunability, and biocompatibility. This study develops a one-step method to modify commercially available screen-printed electrodes (SPE) using laser-induced pyrolysis of DES, consisting of choline chloride and tartaric acid with dissolved nickel acetate and dispersed graphene. The electrodes were patterned using a 532 nm continuous-wave laser for the in situ formation of Ni nanoparticles decorated on graphene sheets directly on the SPE surface (Ni-G/SPE).

View Article and Find Full Text PDF

Cartilage repair remains a critical challenge in orthopaedic medicine due to the tissue's limited self-healing ability, contributing to degenerative joint conditions such as osteoarthritis (OA). In response, regenerative medicine has developed advanced therapeutic strategies, including cell-based therapies, gene editing, and bioengineered scaffolds, to promote cartilage regeneration and restore joint function. This narrative review aims to explore the latest developments in cartilage repair techniques, focusing on mesenchymal stem cell (MSC) therapy, gene-based interventions, and biomaterial innovations.

View Article and Find Full Text PDF

Preparation of CHS-FeO@@ZIF-8 peroxidase-mimic with an ultra-thin hollow layer for ultrasensitive electrochemical detection of kanamycin.

Mikrochim Acta

January 2025

Key Laboratory for Palygorskite Science and Applied Technology of Jiangsu Province, National & Local Joint Engineering Research Center for Mineral Salt Deep Utilization, Huaiyin Institute of Technology, Huaian, 223003, P. R. China.

A highly sensitive and selective electrochemical biosensor was developed for the detection of kanamycin using a core-hollow-shell structured peroxidase-mimic nanozyme, CHS-Fe₃O₄@@ZIF-8. The synthesized CHS-FeO@@ZIF-8 was characterized with scanning electron microscopy, transmission electron microscopy, and X-ray photoelectron spectroscopy. It was found that the CHS-FeO@@ZIF-8 exhibits excellent peroxidase-like activity due to  its ultra-thin hollow layer.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!