In the light of an increased use of premium intraocular lenses (IOL), such as EDOF IOLs, multifocal IOLs or toric IOLs even minor intraoperative complications such as decentrations or an IOL tilt, will hamper the visual performance of these IOLs. Thus, the post-operative analysis of cataract surgeries to detect even minor intraoperative deviations that might explain a lack of a post-operative success becomes more and more important. Up-to-now surgical videos are evaluated by just looking at a very limited number of intraoperative data sets, or as done in studies evaluating the pupil changes that occur during surgeries, in a small number intraoperative picture only. A continuous measurement of pupil changes over the whole surgery, that would achieve clinically more relevant data, has not yet been described. Therefore, the automatic retrieval of such events may be a great support for a post-operative analysis. This would be especially true if large data files could be evaluated automatically. In this work, we automatically detect pupil reactions in cataract surgery videos. We employ a Mask R-CNN architecture as a segmentation algorithm to segment the pupil and iris with pixel-based accuracy and then track their sizes across the entire video. We can detect pupil reactions with a harmonic mean (H) of Recall, Precision, and Ground Truth Coverage Rate (GTCR) of 60.9% and average prediction length (PL) of 18.93 seconds. However, we consider the best configuration for practical use the one with the H value of 59.4% and PL of 10.2 seconds, which is much shorter. We further investigate the generalization ability of this method on a slightly different dataset without retraining the model. In this evaluation, we achieve the H value of 49.3% with the PL of 18.15 seconds.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8530330PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0258390PLOS

Publication Analysis

Top Keywords

pupil reactions
12
reactions cataract
8
cataract surgery
8
surgery videos
8
minor intraoperative
8
post-operative analysis
8
number intraoperative
8
pupil changes
8
detect pupil
8
pupil
6

Similar Publications

Pupil size is a well-established marker of cognitive effort, with greater efforts leading to larger pupils. This is particularly true for pupil size during task performance, whereas findings on anticipatory effort triggered by a cue stimulus are less consistent. For example, a recent report by Frömer et al.

View Article and Find Full Text PDF

Significance: The eye can be used as a potential monitoring window for screening, diagnosis, and monitoring of neurological diseases. Alzheimer's disease (AD) and vascular cognitive impairment (VCI) are common causes of cognitive impairment and may share many similarities in ocular signs. Multimodal ophthalmic imaging is a technology to quantify pupillary light reaction, retinal reflectance spectrum, and hemodynamics.

View Article and Find Full Text PDF

Microtextured microneedles are tiny needle-like structures with micron-scale microtextures, and the drugs stored in the microtextures can be released after entering the skin to achieve the effect of precise drug delivery. In this study, the skin substitution model of Ogden's hyperelastic model and the microneedle array and microtexture models with different geometrical parameters were selected to simulate and analyse the flow of the microtexture microneedle arrays penetrating the skin by the finite-element method, and the length of the microneedles was determined to be 200 μm, the width 160 μm, and the value of the gaps was determined to be 420 μm. A four-pronged cone was chosen as the shape of microneedles, and a rectangle was chosen as the shape of the drug-carrying microneedle.

View Article and Find Full Text PDF

The pupillary direct and consensual reflex is an important non-invasive quick assessment of the neurological state of the eye. Currently, there is no cheap and affordable recording tool for screening and documentation of a relative afferent pupillary defect. We describe how to construct a frugal, do-it-yourself handheld scotopic binocular pupillometer device called Pupilmate.

View Article and Find Full Text PDF

The pupillary light reflex could serve as a valuable method for measuring dynamic responses in the autonomic nervous system (ANS). However, it remains unclear whether physiological conditions such as fasting and dehydration affect pupillary reflexes. In this study, we investigated the effects of fasting and dehydration on pupillary responses using pupillometry.

View Article and Find Full Text PDF