Background: The purpose of this study was to evaluate the biomechanical properties of two different fixation constructs in varus collapse proximal humerus fracture, locking plate with medial support screw and locking plate with intramedullary fibular graft.

Methods: We used 8 pairs of undamaged fresh-frozen humen cadaveric humeri and fibula from patients ranging in age from 62 to 81 years. We simulated a proximal humerus fracture with medial comminution using wedge shaped osteotomy. One group was fixed with locking plate with medial support screws, the other group with locking plate with intramedullary fibular graft. Biomechanical test was carried out using servohydraulic material testing system. We measured displacement of specimens under cyclic load test, maximum failure load, initial stiffness, and mode of failure under increasing load test.

Findings: Under cyclic loading, the displacement of the specimen was significantly less in the locking plate with fibular strut graft group than in the locking plate with medial support screws group. (p = 0.012) Under increasing load test, the Locking plate with fibular strut graft group showed higher values in both maximum failure load and initial stiffness than the Locking plate with medial support screws group, and this was statistically significant. (p = 0.012, p = 0.001).

Interpretation: In biomechanical study, the locking plate with fibular strut graft showed significantly better results in all of the maximum failure load, initial stiffness, and gap depletion compared to the locking plate with medial support screws.

Level Of Evidence: Level IV.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clinbiomech.2021.105510DOI Listing

Publication Analysis

Top Keywords

locking plate
48
plate medial
24
medial support
24
locking
12
plate
12
plate intramedullary
12
intramedullary fibular
12
support screws
12
screws group
12
maximum failure
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!