Preparation of highly stable Pickeringemulsions stabilized by food grade particles especially with low concentrations is of concern. In this study, the effects of two-step emulsification procedure with different sequential ultrasonic processes on the storage stability, droplets size, zeta potential, microstructures as well as the rheological behaviors of surimi particles-stabilized Pickeringemulsions with 0.6 oil-water ratio were investigated. The results showed that the surimi particles based-emulsions prepared by the homogenization-ultrasonic (H-U) or ultrasonic-homogenization (U-H) method both possessed excellent physical stability during 14 days storage. Particularly, the stability index of emulsions all exceeded 99.5% in the U-H groups. The confocal laser scanning microscopy (CLSM) and cryo-scanning electron microscope (cryo-SEM) images provide evidence that more particles attached on the oil-water interfaces and the network structures formed via particle-particle interactions obviously arrested phase separation in H-U and U-H emulsions. Moreover, the Pickering emulsions obtained by two-step method all exhibited higher viscosity and storage modulus values, which were also conducive to the special storage stability of samples. In short, the storage stability of protein based-Pickering emulsions can be enhanced using homogenization-ultrasonic (H-U) or ultrasonic-homogenization (U-H) procedure.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8560627 | PMC |
http://dx.doi.org/10.1016/j.ultsonch.2021.105802 | DOI Listing |
ACS Appl Mater Interfaces
December 2024
Key Laboratory of Synthetic and Biological Colloids, Ministry of Education, School of Chemical and Material Engineering, Jiangnan University, 214122 Jiangsu, China.
Nanometric solid solution alloys are utilized in a broad range of fields, including catalysis, energy storage, medical application, and sensor technology. Unfortunately, the synthesis of these alloys becomes increasingly challenging as the disparity between the metal elements grows, due to differences in atomic sizes, melting points, and chemical affinities. This study utilized a data-driven approach incorporating sample balancing enhancement techniques and multilayer perceptron (MLP) algorithms to improve the model's ability to handle imbalanced data, significantly boosting the efficiency of experimental parameter optimization.
View Article and Find Full Text PDFAdv Sci (Weinh)
December 2024
Institute of Materials Science, Technische Universität Darmstadt, Peter-Grünberg-Str. 2, D-64287, Darmstadt, Germany.
The design of cathode/electrolyte interfaces in high-energy density Li-ion batteries is critical to protect the surface against undesirable oxygen release from the cathodes when batteries are charged to high voltage. However, the involvement of the engineered interface in the cationic and anionic redox reactions associated with (de-)lithiation is often ignored, mostly due to the difficulty to separate these processes from chemical/catalytic reactions at the cathode/electrolyte interface. Here, a new electron energy band diagrams concept is developed that includes the examination of the electrochemical- and ionization- potentials evolution upon batteries cycling.
View Article and Find Full Text PDFSci Rep
December 2024
Metanotitia Inc, Building C4, Science and Technology Innovation Headquarters, Shenzhen (Harbin) Industrial Park, 288 Zhigu Street, Songbei District, Harbin, 150029, China.
Dried blood spot (DBS) sampling offers significant advantages over conventional blood collection methods, such as reduced sample volume, minimal invasiveness, suitability for home-based sampling, and ease of transport. However, understanding the effects of variable storage temperatures and times on metabolite stability is crucial due to varying intervals and delivery conditions between sample collection and metabolomics analysis. To minimize biological variances, all samples were collected from the same individual simultaneously and stored at three different temperatures (4 °C, 25 °C, and 40 °C) for diverse time points (3, 7, 14, and 21 days).
View Article and Find Full Text PDFSci Rep
December 2024
Department of Applied Biomedical Science, Faculty of Health Sciences, University of Malta, Msida, 2080, MSD, Malta.
There is much interest in analysing RNA, particularly with RNA Sequencing, across both research and diagnostic domains. However, its inherent instability renders it susceptible to degradation. Given the imperative for RNA integrity in such applications, proper storage and biobanking of blood samples and successful subsequent RNA isolation is essential to guarantee optimal integrity for downstream analyses.
View Article and Find Full Text PDFSci Bull (Beijing)
December 2024
School of Metallurgy and Environment, Central South University, Changsha 410083, China; Engineering Research Center of the Ministry of Education for Advanced Battery Materials, Central South University, Changsha 410083, China; National Energy Metal Resources and New Materials Key Laboratory, Central South University, Changsha 410083, China. Electronic address:
The dendrite and corrosion issues still remain for zinc anodes. Interface modification of anodes has been widely used for stabilizing zinc anodes. However, it is still quite challenging for such modification to simultaneously suppress zinc dendrites and corrosion issues.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!