A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Programmable-Printing Paper-Based Device with a MoS NP and Gmp/Eu-Cit Fluorescence Couple for Ratiometric Tetracycline Analysis in Various Natural Samples. | LitMetric

Paper-based fluorescence devices, with smartphone aids, bring considerable operation convenience for tetracycline (TC) sensing. Nevertheless, they must meet the challenge in real determination against complicated backgrounds. Considering that, we present a programmable-printing paper-based device and then apply it to TC determination for various natural samples. MoS NPs and Gmp/Eu-Cit are synthetized as composite probes. A static quenching process is found with MoS NP fluorescence at 430 nm, while significant magnification of Gmp/Eu-Cit emission is obtained at 617 nm, establishing a valuable ratiometric indicator. Remarkably, two-stage programmable printing maximizes the proposed sensing capability. A transitive device, containing a gradually changing amount of a certain probe, is prepared to sense TC. With a homemade smartphone application and 3D-printed measurement chamber, the corresponding signals are examined to explore optimal setups. These setups are automatically processed to prepare the final-version device, not requiring manual operations. Benefitting from this interesting feature, the proposed device gains many rewards in performances. It effectively senses TC in a wide range from 12.7 nM to 80 μM and simultaneously provides naked eye-legible signals and smartphone-based readouts with confident selectivity and stability. This device is consequently applied for various samples of soil, river water, milk, and serum and meets well with HPLC-MS and recovery tests.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acssensors.1c01448DOI Listing

Publication Analysis

Top Keywords

programmable-printing paper-based
8
paper-based device
8
natural samples
8
device
6
device mos
4
mos gmp/eu-cit
4
gmp/eu-cit fluorescence
4
fluorescence couple
4
couple ratiometric
4
ratiometric tetracycline
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!