A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 144

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 144
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 212
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 998
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3138
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A method for determination of aldosterone concentrations of six adrenal venous serum samples during a single LC/ESI-MS/MS run using a sextet of Girard reagents. | LitMetric

The accurate quantification of aldosterone (ALD) in adrenal tributary venous serum/plasma collected by a super-selective adrenal venous sampling (ssAVS) technique has become a definitive procedure to identify the forms (laterality) of primary aldosteronism (PA) and the location of the affected segment(s), and to subsequently make the treatment decision. In this study, a stable isotope-dilution LC/ESI-MS/MS-based method was developed and validated for the determination of the ALD concentrations of the six ssAVS serum samples during a single run. A sextet of Girard reagents was used to convert ALD to the derivatives having different masses for each sample. Based on the validation tests, satisfactory specificity, precision and accuracy were observed and the matrix effect was found to be acceptable. The developed method was used for the analysis of the ssAVS serum samples from eight PA patients. The batch analysis of the six samples permitted the direct comparison of the ALD concentrations between the samples and enhanced to determine the laterality and location of the affected segment(s). The total analysis time after the sample purification was also reduced to 1/3 for the 24 samples by the sample-sextuplex procedure, which was also an advantage of the developed method.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpba.2021.114423DOI Listing

Publication Analysis

Top Keywords

serum samples
12
adrenal venous
8
samples single
8
sextet girard
8
girard reagents
8
location segments
8
ald concentrations
8
ssavs serum
8
developed method
8
samples
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!