Segmentation of lumen and vessel contours in intravascular ultrasound (IVUS) pullbacks is an arduous and time-consuming task, which demands adequately trained human resources. In the present study, we propose a machine learning approach to automatically extract lumen and vessel boundaries from IVUS datasets. The proposed approach relies on the concatenation of a deep neural network to deliver a preliminary segmentation, followed by a Gaussian process (GP) regressor to construct the final lumen and vessel contours. A multi-frame convolutional neural network (MFCNN) exploits adjacency information present in longitudinally neighboring IVUS frames, while the GP regression method filters high-dimensional noise, delivering a consistent representation of the contours. Overall, 160 IVUS pullbacks (63 patients) from the IBIS-4 study (Integrated Biomarkers and Imaging Study-4, Trial NCT00962416), were used in the present work. The MFCNN algorithm was trained with 100 IVUS pullbacks (8427 manually segmented frames), was validated with 30 IVUS pullbacks (2583 manually segmented frames) and was blindly tested with 30 IVUS pullbacks (2425 manually segmented frames). Image and contour metrics were used to characterize model performance by comparing ground truth (GT) and machine learning (ML) contours. Median values (interquartile range, IQR) of the Jaccard index for lumen and vessel were 0.913, [0.882,0.935] and 0.940, [0.917,0.957], respectively. Median values (IQR) of the Hausdorff distance for lumen and vessel were 0.196mm, [0.146,0.275]mm and 0.163mm, [0.122,0.234]mm, respectively. Also, the mean value of lumen area predictions, and limits of agreement were -0.19mm, [1.1,-1.5]mm, while the mean value and limits of agreement of plaque burden were 0.0022, [0.082,-0.078]. The results obtained with the model developed in this work allow us to conclude that the proposed machine learning approach delivers accurate segmentations in terms of image metrics, contour metrics and clinically relevant variables, enabling its use in clinical routine by mitigating the costs involved in the manual management of IVUS datasets.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.media.2021.102262 | DOI Listing |
Catheter Cardiovasc Interv
January 2025
Lancashire Cardiac Centre, Blackpool, UK.
Coronary calcification is a major factor leading to stent under-expansion, and subsequent adverse events. This meta-analysis aimed to evaluate the short and long‑term outcomes of rotational atherectomy (RA), followed by modified balloon (cutting or scoring) (MB) versus plain balloon before drug‑eluting stent implantation for calcified coronary lesions. We searched PubMed, Web of Science (WOS), Scopus, and the Cochrane Library Central Register of Controlled Trials (CENTRAL), from inception until 30 January 2024.
View Article and Find Full Text PDFVascular
January 2025
Division of Vascular Surgery, Medical University of South Carolina, Charleston, SC, USA.
Objectives: Mal-deployment of the thoracic endovascular aortic repair (TEVAR) stent graft during a frozen elephant trunk (FET) procedure for an acute type A aortic dissection (ATAAD) leads to devastating complications. We report a hemiarch replacement with TEVAR stent graft covering the aortic arch vessels salvaged through an endovascular approach.
Methods: A 69-year-old man with ATAAD in 2018, status post-hemiarch repair with TEVAR, presented in 2023 with progressive dizziness/syncope and lower extremity hypertension with inability to tolerate anti-hypertensives.
J Magn Reson Imaging
January 2025
Department of Radiology, Endeavor Health, Evanston, Illinois, USA.
Background: Luminal and hemodynamic evaluations of the cervical arteries inform the diagnosis and management of patients with cervical arterial disease.
Purpose: To demonstrate a 3D nonenhanced quantitative quiescent interval slice-selective (qQISS) magnetic resonance angiographic (MRA) strategy that provides simultaneous hemodynamic and luminal evaluation of the cervical arteries.
Study Type: Prospective.
Mediastinum
May 2024
Department of Interventional Radiology, Division of Diagnostic Imaging, University of Texas MD Anderson Cancer Center, Houston, TX, USA.
The mediastinal vasculature can be affected by various etiologies in cancer patients. Both direct and indirect sequela of cancer may result in life-threatening clinical presentations. Tumor growth may cause vessel narrowing and decreased blood flow from either extrinsic mass effect, invasion into the vascular wall, or tumor thrombus within the lumen.
View Article and Find Full Text PDFJ Cardiothorac Surg
January 2025
Cerrahpasa Medical Faculty, Department of Cardiovascular Surgery, Istanbul University-Cerrahpasa, Istanbul, Turkey.
Objectives: Despite the advances in medicine, aortic dissection remains a cardiac surgery emergency with high mortality and morbidity rates. This study examined the effects of the Glue + Felt technique, which uses biological glue and felt to repair the proximal anastomotic site, on the outcomes of patients with acute type A aortic dissection.
Methods: A total of 108 patients who underwent surgery for acute type A aortic dissection at our clinic between 2007 and 2020 were included in the study.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!