A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Reliability of range-of-motion measurements of healthy dogs examined while walking on a treadmill. | LitMetric

Reliability of range-of-motion measurements of healthy dogs examined while walking on a treadmill.

Am J Vet Res

From the Clinic for Small Animal Surgery and Reproduction and Department of Veterinary Sciences, Ludwig-Maximilians-Universität München, 80539 Munich, Germany.

Published: November 2021

Objective: To determine the reliability of range-of-motion (ROM) measurements and describe physiologic differences in ROM or habituation effects during gait analysis of healthy dogs walking on a treadmill.

Animals: 11 orthopedically normal dogs.

Procedures: ROM of appendicular joints was determined for each dog while walking on a treadmill on 3 consecutive examination days and once again 6 weeks later. Significant differences in ROM between examination days were determined and quantified. As a measure of reproducibility, the coefficient of variation for repeated measurements was calculated, as were the minimum differences necessary to distinguish between physiologic variation and true change in ROM.

Results: Mean ROM of the shoulder, elbow, and carpal joints varied among examination days between 29.9° and 33.1°, 49.4° and 52.8°, and 7.7° and 88.1°, respectively. Mean associated minimum differences were 12.0°, 14.1°, and 35.6°. Mean ROM of the hip, knee, and tarsal joints varied between 32.9° and 35.8°, 33.7° and 36.8°, and 31.7° and 33.5°, respectively. Mean associated minimum differences were 16.2°, 14.0°, and 9.2°. Only ROM of the elbow joint was reproducible to a small degree. Few systematic effects were detected.

Conclusions And Clinical Relevance: Measurement of ROM in healthy dogs walking on a treadmill was shown to be diagnostically unreliable owing to high variation among examination days. However, random physiologic fluctuations could be distinguished from systematic effects, demonstrating the importance of reliably applicable threshold values for follow-up treadmill examinations. The applicability of the minimum differences determined here to orthopedically diseased dogs remains to be determined.

Download full-text PDF

Source
http://dx.doi.org/10.2460/ajvr.82.11.897DOI Listing

Publication Analysis

Top Keywords

examination days
16
minimum differences
16
healthy dogs
12
walking treadmill
12
reliability range-of-motion
8
rom
8
differences rom
8
dogs walking
8
joints varied
8
associated minimum
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!