A 72-year-old male developed a late-onset infection of an internal fixation device caused by Although often considered contaminants, bacteria from the genus may also be pathogens. We also summarize cases from the Veteran Health Administration (VHA) from which isolates were recovered and review the relevant literature. Using the national VHA database, we identified patients with cultures that grew spp. We also review published clinical reports describing spp. as a cause of infections. Between January 2000 and September 2020, 18 cases had spp. Of those, isolates were regarded as pathogens for seven cases; all involved prosthetic material that was consequently removed. Two patients had internal fixation devices whereas the remaining five were patients with a central venous catheter. For patients with prosthetic material, recovery of spp. from device-related clinical cultures should prompt consideration of device removal when possible.

Download full-text PDF

Source
http://dx.doi.org/10.1089/sur.2021.133DOI Listing

Publication Analysis

Top Keywords

central venous
8
internal fixation
8
prosthetic material
8
spp
5
orthopedic implant-associated
4
implant-associated central
4
venous catheter-associated
4
catheter-associated infections
4
infections caused
4
caused spp
4

Similar Publications

Background: People undergoing major orthopaedic surgery are at increased risk of postoperative thromboembolic events. Low molecular weight heparins (LMWHs) are recommended for thromboprophylaxis in this population. New oral anticoagulants, including direct factor Xa inhibitors, are recommended as alternatives.

View Article and Find Full Text PDF

One-lung ventilation is commonly used in lateral open chest surgery; however, it can increase pulmonary vascular resistance, which negatively affects Fontan circulation. Nevertheless, one-lung ventilation has a positive indication in post-Fontan patients. It allows surgery with lateral minimally invasive thoracotomy, which does not require a median sternotomy.

View Article and Find Full Text PDF

Background: In general, it is relatively easy to remove peripherally inserted central venous catheter (PICC) by gentle traction without any complications. However, the removal of PICC can be challenging occasionally. If the standard interventions fail to remove the catheter, there are no clear recommendations about what to do.

View Article and Find Full Text PDF

Timely and effective rescue of critically ill children no longer solely relies on advanced medical technology; vascular access plays a pivotal role. Best practice recommendations for nursing in vascular access are critical for ICU patients. However, clear guidelines for the maintenance of external infusion connection devices remain lacking.

View Article and Find Full Text PDF

Background And Objective: The aim of this retrospective observational case-control study was to examine the significance of different renal Doppler marker variations within the initial 24-hour period as potential predictors of Acute Kidney Injury (AKI) in patients with sepsis.

Methods: A total of 198 sepsis patients were enrolled and categorized into two groups: the AKI group (n = 136) and the non-AKI group (n = 62). Three renal Doppler indices, Renal Resistive Index (RRI), Power Doppler Ultrasound (PDU) score and Renal Venous Stasis Index (RVSI), were measured within 6h (T0) and at 24h (T1) after ICU admission.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?