Cannulated screw fixation is widely used in the treatment of femoral neck fractures. During surgery, we often face the situation that a guide wire needs to be adjusted because of poor positioning in the femoral neck. It is difficult to adjust the direction of the guide wire in the neck of the femur due to its elasticity. This study developed a practical technique to adjust the guide wire to the correct position. When the direction of insertion of the guide wire has deviated, first, measure the length of the guide wire. Second, select the appropriate cannulated screw based on the measurement, and screw the cannulated screw in along the direction of the guide wire to Ward's triangle. Then return the guide wire to the front of the cannulated screw. At this time, the cannulated screw can be used as a built-in guide, and a screwdriver can be used to fine-tune the position of the screw to the optimal direction under the X-ray guidance. Finally, the cannulated screw is screwed in in this direction until it passes through the Ward triangle area, and the guide wire is inserted. This technique can help doctors insert a guide wire more quickly and accurately, reducing intraoperative injury and the operation time.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8654675PMC
http://dx.doi.org/10.1111/os.12994DOI Listing

Publication Analysis

Top Keywords

guide wire
40
cannulated screw
24
femoral neck
12
guide
11
wire
10
screw
9
neck fractures
8
direction guide
8
cannulated
7
direction
5

Similar Publications

Introduction: Numerous orthopaedic procedures including dynamic hip screw plating and various osteotomies require placement of a reference guide pin or K wire to direct bone cuts or for drilling screw holes. Appropriate positioning of these wires is a critical component of surgery. Irrespective of whether one is a seasoned surgeon or an apprentice, these wires often need repositioning and readjustment.

View Article and Find Full Text PDF
Article Synopsis
  • The transmembrane potential is crucial for cellular functions like signaling and energy production, with Rhodamine voltage reporters (RhoVRs) serving as small, non-invasive sensors that can detect voltage changes, especially in mitochondria.
  • Extensive simulations and free-energy calculations revealed that the orientation of RhoVRs relative to membranes, influenced by their polarized functional groups, significantly impacts their voltage sensitivity and localization within cells.
  • The study's findings on the relationship between the chemical structure of RhoVRs and their membrane behavior offer valuable insights for designing fluorescent dyes that better detect voltage changes.
View Article and Find Full Text PDF

Selecting an appropriate microcatheter tip shape for paraclinoid aneurysms is difficult. Therefore, we devised an original simple and uniform three-dimensional (3D) spiral-shaping method of microcatheter and validated the characteristics and usefulness of this method for coil embolization of paraclinoid aneurysms using patient-specific silicone models. These silicone models were produced based on clinical data from four patients with four paraclinoid aneurysms that underwent endovascular treatment using the 3D spiral-shaping method.

View Article and Find Full Text PDF

Physical Simulation Experiment on the Rock Breaking Efficiency of Pulse Type Controllable Shock Wave.

ACS Omega

December 2024

Shenmu Ningtiaota Mining Company, Shaanxi Coal and Chemical Industry Group, Shenmu, Shaanxi 719300, China.

Given that conducting controllable shock wave tests in actual rock formations underground in coal mines affects coal mine production with the parameters required for equipment design and incurs significant costs, a series of ground tests were conducted separately. First, the impact of energy storage on rock breaking efficiency was analyzed. Then, physical simulation experiments were conducted on the differential efficiency of controllable shock waves on high-strength cement, sandstone, granite, solid granite, and limestone.

View Article and Find Full Text PDF

Transjugular transcatheter edge-to-edge mitral valve repair in a patient with functional mitral regurgitation: a case report.

Eur Heart J Case Rep

January 2025

Department of Cardiovascular Medicine, Sendai Kousei Hospital, 1-20 Tsutsumidori-amamiya, Aoba Ward, Sendai, Miyagi 9810914, Japan.

Article Synopsis
  • The transcatheter edge-to-edge mitral valve repair (M-TEER) using the MitraClip system is usually done via the transfemoral approach, but the transjugular approach can be a viable alternative when the former isn't possible.
  • A 57-year-old man with heart failure and severe functional mitral regurgitation could not undergo the transfemoral approach due to an occluded inferior vena cava, leading to the decision to use the transjugular technique instead.
  • The procedure was successful with no complications, significantly reducing the patient's mitral regurgitation, and he showed sustained improvement a year later.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!