Background: Scant data exist on long-term outcomes, including death, in patients with complica-tions related to transvenous lead extractions (TLE).

Aims: We sought to characterize the population and examine the outcomes including risk factors for in-hospital complications and 12-month mortality and morbidity related to the complications in a large administrative database of patients undergoing TLE.

Results: From the database of patients hospitalized for cardiovascular diseases and included in the Silesian Cardiovascular Database (SILCARD) registry, we selected the admissions of those who underwent TLE according to the appropriate ICD-9 codes. The patients were divided into two groups based on whether they did or did not manifest any complications during their hospitalization for the TLE procedure. Between 2007 and 2019, we found a total of 835 patients who underwent TLE. TLE-related complications occurred in 56 patients (6.7%) of the Complications-Yes group while no complications were recorded in 779 (93.3%) patients of the Complications-No group. A significant difference in the rate of all-cause mortality (23.9% vs. 6.5%; P <0.001) and major adverse cardiac events (MACE) (58.7% vs. 39.4%; P = 0.01) between the Complications-Yes and Complications-No groups were recorded. Multivariable analysis of the entire study population revealed that prior dialysis, chronic kidney disease, and ventricular tachycardia were independent factors of a higher risk of TLE-related in-hospital complications. Multivariable analysis of the patients discharged from the hospital after the TLE procedure showed that TLE-related complications, a history of heart failure, and older age independently affected 12-month mortality.

Conclusions: The presence of TLE-related in-hospital complications increased 12-month mortality.

Download full-text PDF

Source
http://dx.doi.org/10.33963/KP.a2021.0141DOI Listing

Publication Analysis

Top Keywords

transvenous lead
8
silcard registry
8
outcomes including
8
database patients
8
underwent tle
8
patients
7
complications
5
impact complications
4
complications transvenous
4
lead extraction
4

Similar Publications

A young man in his 30s presented to us with multiple episodes of syncope and exertional dyspnoea for the last 2 weeks. He was diagnosed with squamous cell carcinoma of the lower one-third of the oesophagus in 2021 for which he was treated with neoadjuvant chemoradiotherapy, followed by McKeown oesophagectomy. At 2-year follow-up, he had developed a soft tissue swelling in the scalp, which was diagnosed as a tumour recurrence and radiotherapy was initiated.

View Article and Find Full Text PDF

This case details the successful implantation of a leadless pacemaker following the extraction of transvenous leads in a 72-year-old female patient with a complex cardiovascular history. The patient had undergone a series of cardiac interventions, including a recent percutaneous tricuspid valve repair with a metal clip implant due to severe regurgitation. After presenting with an infection at the pacemaker site, methicillin-resistant Staphylococcus hominis was identified, necessitating the removal of the entire pacing system.

View Article and Find Full Text PDF

Objective: To compare the paced QRS duration on different sites in age-, gender-, and indication-matched patients implanted with Micra leadless pacemakers and conventional transvenous pacemakers (TV-PM).

Method: A total of 82 patients from Xinhua Hospital, Shanghai Jiaotong University, were enrolled, including two groups of 41 patients matched according to gender, age, and pacemaker indications, who underwent Micra and TV-PM implantations, respectively. The baseline data of the patients, the pacing site described using three- and nine-partition methods, and the paced QRS duration on 12-lead electrocardiogram were then analyzed.

View Article and Find Full Text PDF

Leadless Pacing: Current Status and Ongoing Developments.

Micromachines (Basel)

January 2025

Section of Electrophysiology, Division of Cardiology, Department of Internal Medicine, Rush University Medical Center, 1653 W. Congress, Chicago, IL 60612, USA.

Although significant strides have been made in cardiac pacing, the field is still evolving. While transvenous permanent pacing is highly effective in the management of bradyarrhythmias, it is not risk free and may result in significant morbidity and, rarely, mortality. Transvenous leads are often the weakest link in a pacing system.

View Article and Find Full Text PDF