Purpose: To compare the iris parameters (iris thickness [IT] and volume) measured at different locations on iris determined using iris base (IB) and scleral spur (SS) in healthy Saudi eyes and factors affecting the differences.

Methods: Healthy eyes of Saudi persons were evaluated using anterior segment optical coherence tomography (AS-OCT). The IT was measured using Image J software and OCT scans in the horizontal axis in light on and light off condition. First IB was used as reference, and then, SS was used as reference for these measurements.

Results: One hundred healthy eye's AS-OCT scan was studied. The IT at the temporal side of the horizontal axis at 750 µ away from IB with lights on was 0.526 ± 0.08 µ, whereas it was 0.52 ± 0.08 µ from SS. The difference was significantly more in IB than SS method ( = 0.005). This difference if IT in SS and IB method was not affected by gender (Mann-Whitney = 0.3), type of refractive error (K W = 0.7), and level of illumination (K W = 0.7).

Conclusion: IT and IV measured using IB provided reliable data but overestimates compared to SS method. In the absence of SS visibility, IB could be alternative to assess iris parameters.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8486035PMC
http://dx.doi.org/10.4103/1319-4534.325788DOI Listing

Publication Analysis

Top Keywords

iris thickness
8
volume measured
8
iris base
8
base scleral
8
scleral spur
8
optical coherence
8
coherence tomography
8
iris parameters
8
horizontal axis
8
difference method
8

Similar Publications

Purpose: Using a fully automated multitask deep learning method, which enabled simultaneous segmentation and quantification of all major anterior segment structures with swept-source optical coherence tomography (SS-OCT), we aimed to investigate the three-dimensional (3D) alterations in iris morphology before and after implantable collamer lens (ICL) surgery.

Methods: All enrolled patients underwent anterior segment SS-OCT (ANTERION) within one week before and after ICL surgery. A multitask network automatically performed iris SS-OCT image segmentation and quantitative measurements of 3D iris morphology (iris thickness and volume of the inner 1-mm annular area and the outer 1-2-mm annular area, iris curvature [I-Curve], and iris smooth index [SI]).

View Article and Find Full Text PDF

Introduction: Cataract surgery has been reported to have a reducing effect on intraocular pressure (IOP) in glaucomatous and non-glaucomatous eyes. This effect seems to be more noticeable in eyes with narrow angles (NAs) than in eyes with open angles (OAs). Decrease in IOP may be a result of the increase in anterior chamber angle (ACA) and Schlemm canal (SC) after cataract surgery.

View Article and Find Full Text PDF

Purpose: A relative afferent pupillary defect (RAPD) is a characteristic clinical sign of optic neuritis (ON). Here, we systematically evaluated ultrasound pupillometry (UP) for the detection of an RAPD in patients with ON, including a comparison with infrared video pupillometry (IVP), the gold standard for objective pupillometry.

Materials And Methods: We enrolled 40 patients with acute (n = 9) or past (n = 31) ON (ON+), 31 patients with multiple sclerosis (MS) without prior ON, and 50 healthy controls (HC) in a cross-sectional observational study.

View Article and Find Full Text PDF

Photodegradation of steroid hormone micropollutants with palladium-porphyrin coated porous PTFE of varied morphological and optical properties.

Water Res

December 2024

Institute for Advanced Membrane Technology (IAMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany. Electronic address:

In flow-through reactors, the photodegradation rate can be improved by enhancing contact and increasing the photocatalyst loading. Both can be attained with a higher surface-to-volume ratio. While previous studies focused on thin membranes (30 - 130 µm) with small pore sizes of 20 - 650 nm, this work employed poly(tetrafluoroethylene) (PTFE) supports, of which pore sizes are in the order of 10 µm, while the porosities and thicknesses are variable (22.

View Article and Find Full Text PDF

Purpose: To compare iridian Swept-Source Anterior Segment OCT (SS-AS-OCT) and microbiological features in Aqueous Humor (AH) in patients with Fuchs Uveitis Syndrome (FUS) and Posner-Schlossman Syndrome (PSS).

Methods: Comparative, retrospective-prospective single center study examining 131 eyes from 66 patients, including 33 eyes with PSS, 37 eyes with FUS, and 61 healthy eyes. AH samples were collected from affected eyes in all patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!