Background: The ability of physical therapists (PTs) to accurately identify and reliably measure phoria/tropia is critical in the differential diagnosis of individuals with acute vestibular syndrome and concussion/mild traumatic brain injury.

Objectives: To determine if PTs may reliably measure phoria and to determine the reliability of two dissociating tests of phoria, the prism neutralized Maddox rod test and modified Thorington method, in normal adults with artificially created phoria.

Methods: Thirty adults (mean age 24.87 ± 4.74 years) were randomly assigned to wear trial lenses (1, 2, 4, or 6 pd prism left, plain glass right) to create phoria. In sitting and supine, phoria was measured using prism neutralized Maddox rod test and modified Thorington method. Mean, SD, and range of first neutral endpoint were calculated for each examiner. Percentage of trials in agreement (≤ 2 and 4 pd); comparisons within the linear mixed effects regression model; and inter-rater reliability between examiners was calculated with the intra-class correlation coefficient (ICC).

Results: Participants underwent 20 measurements by each examiner. Trial agreement between examiners was 74% (range 13%-100%) in horizontal and 91% (range 63%-100%) in vertical plane. Maddox rod test had significantly different means between two examiners ( < .05). Modified Thorington test had no significant difference. The Maddox rod test had a significant examiner main effect, examiner 2 always scored lower. Inter-rater correlation coefficient for each test was significant at level of  < .01 (ICC ≥ 0.67 ≤ 0.94) except for modified Thorington test in supine, horizontal plane with  < .05 (ICC ≥ 0.38).

Conclusion: PTs may reliably measure artificially created phorias using prism neutralized Maddox rod test and modified Thorington method.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8513437PMC
http://dx.doi.org/10.1002/lio2.653DOI Listing

Publication Analysis

Top Keywords

maddox rod
12
rod test
12
reliability dissociating
8
dissociating tests
8
tests phoria
8
artificially created
8
normal adults
8
reliably measure
8
prism neutralized
8
neutralized maddox
8

Similar Publications

[Efficacy of modified nasal transposition of the split lateral rectus muscle for large-angle exotropia from oculomotor nerve palsy].

Zhonghua Yan Ke Za Zhi

January 2025

Tianjin Eye Hospital, Nankai University Affiliated Eye Hospital, Clinical College of Ophthalmology of Tianjin Medical University, Tianjin Eye Institute, Tianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin300020, China.

To explore the efficacy of the modified lateral rectus muscle splitting and nasal transposition surgery in treating large-angle exotropia caused by oculomotor nerve palsy and its impact on ocular motility. Retrospective case series study. Data was collected from patients diagnosed with large-angle exotropia due to oculomotor nerve palsy and treated by modified lateral rectus muscle splitting and nasal transposition surgery at the Tianjin Eye Hospital from January 2020 to October 2023.

View Article and Find Full Text PDF

The Maddox rod: Revisiting the optics.

Ophthalmic Physiol Opt

December 2024

Sight Specialists, Gold Coast, Queensland, Australia.

The Maddox rod is a staple in the assessment of strabismus. However, its optics mechanism is puzzling. How is it that an orthogonal line focus is formed? Surprisingly, few texts offer an explanation and those that do either provide insufficient detail, contain misleading information or are difficult to follow.

View Article and Find Full Text PDF

Augmented-dose surgery based on the single Maddox rod test for acute acquired comitant esotropia.

J AAPOS

December 2024

State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China. Electronic address:

Purpose: To compare the outcomes of augmented-dose surgery for acute acquired comitant esotropia (AACE) based on either the single Maddox rod test (SMRT), or the prism and alternate cover test (PACT), in cases where there is a clinically significant difference in the deviation using the two tests.

Methods: The medical records of AACE patients who underwent augmented-dose surgery with a difference of ≥5 in preoperative deviations on PACT and SMRT were reviewed retrospectively. Augmented-dose surgery was based on the SMRT or PACT.

View Article and Find Full Text PDF

In congenital stationary night blindness, type 2 (CSNB2)-a disorder involving the Ca1.4 (L-type) Ca channel-visual impairment is mild considering that Ca1.4 mediates synaptic release from rod and cone photoreceptors.

View Article and Find Full Text PDF

Purpose: To report the long-term outcomes of bilateral symmetrical superior oblique (SO) nasal tenotomy in patients with large A-pattern exotropia (≥25 prism diopter [PD]).

Methods: This retrospective study was conducted on 15 patients (aged: 4-28 years) of large A-pattern exotropia. An A-pattern was defined as >10 PD difference between up and down gaze at 6 m by use of the alternate prism cover test.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!