Vitamin E incorporation into highly cross-linked polyethylene (HXLPE) has been introduced to improve wear resistance, and vitamin E incorporated HXLPE (VEPE) has been used in total hip arthroplasty.The aim of this meta-analysis was to investigate the wear properties of VEPE in clinical practice by synthesizing the data provided in randomized clinical trials.The effects on implant stability, functional outcomes and revision rate of VEPE were also compared with those of HXPLE or ultra-high molecular weight polyethylene (UHMWPE).Literature searches were conducted on 1 January 2020 using MEDLINE, EMBASE, Cochrane and ClinicalTrials.gov databases. Randomized controlled trials (RCTs) comparing the aforementioned parameters between VEPE and standard HXPLE/UHMWPE liners were included.Methodological quality and the bias of the included studies were analysed. Meta-analyses were performed using the Review Manager software.Nine RCTs met the eligibility criteria and were included. At early and mid-term follow-up, the vertical penetration and the total penetration of the femoral head were both significantly reduced in the VEPE group. The steady state wear rate of the VEPE group was also remarkably lower.However, at two-year follow-up, significantly increased cup migration was observed in the VEPE group. Moreover, the mid-term clinical outcomes of the VEPE group were worse, while the total revision rates between the two groups were not significantly different.The limited number of included studies may compromise our conclusion regarding clinical outcomes of the VEPE bearing surface. More RCTs with longer follow-up periods are needed to further investigate the effects of VEPE in total hip arthroplasty. Cite this article: 2021;6:759-770. DOI: 10.1302/2058-5241.6.200072.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8489480 | PMC |
http://dx.doi.org/10.1302/2058-5241.6.200072 | DOI Listing |
Hip Int
November 2024
Department of Clinical Sciences at Danderyd Hospital, Unit of Orthopaedics, Karolinska Institute, Stockholm, Sweden.
Background: In a previous study we have shown that a cemented vitamin E-doped highly cross-linked polyethylene (VEPE) compared to a conventional polyethylene cup in total hip arthroplasty (THA) has a slightly higher proximal migration but significantly lower wear rates up to 2 years after surgery. In this follow-up study we investigated the same cohort at 6 years.
Methods: This was a double-blinded, non-inferiority, randomised controlled trial on patients with osteoarthritis, with a mean age of 66 years.
Sci Rep
September 2024
Department of Orthopaedics and Trauma Surgery, University Hospital Erlangen, 91054, Erlangen, Germany.
The present Bayesian network meta-analysis compared different types of polyethylene liners in total hip arthroplasty (THA) in terms of wear penetration (mm/year) and rate of revision. The type of liners compared were the crosslinked ultra-high molecular weight polyethylene (CPE/UHMWPE), Vitamin E infused highly cross-linked polyethylene (HXLPE-VEPE), modified cross-linked polyethylene (MXLPE), highly cross-linked polyethylene (HXLPE), Cross-linked polyethylene (XLPE). This study was conducted according to the PRISMA extension statement for reporting systematic reviews incorporating network meta-analyses of healthcare interventions.
View Article and Find Full Text PDFPurpose: The aim of this cross-sectional study was to compare survival, clinical and radiographic results of total knee arthroplasty (TKA) with vitamin E-stabilized polyethylene (VEPE) or conventional polyethylene (CPE) at a minimum of 7-year follow-up.
Methods: Patients who underwent primary TKA between 2011 and 2015, receiving the same cemented rotating platform knee design with VEPE or CPE tibial inserts, were identified. Patients were contacted for clinical and radiographic follow-up.
J Am Acad Orthop Surg
November 2024
From the Hip, Tumors and Pediatric Orthopedic Unit, University Clinic of Navarra, Navarra, Spain (Lamo-Espinosa, Gómez-Álvarez, and San-Julián), the Institute for Research on Muscuoskeletal Disorders, Valencia Catholic University, Valencia, Spain (Mariscal), and the La Fe University and Polytechnic Hospital, Valencia, Spain (Mariscal).
Introduction: The goal of this study was to assess the efficacy and safety of vitamin E cup cross-linked polyethylene (VEPE) liners compared with standard polyethylene (PE) liners in total hip arthroplasty.
Methods: A systematic search of the PubMed, EMBASE, Scopus, and Cochrane Collaboration Library databases was conducted. The evaluated outcomes were radiological parameters, functional scores (Harris Hip Score, Numeric Rating Scale, and Activity Scale from the University of California), and adverse events.
J Arthroplasty
July 2024
Department of Orthopaedic Surgery, Copenhagen University Hospital Hvidovre, Hvidovre, Denmark; Faculty of Health Sciences, Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!