Objective: To analyze the clinical outcomes of all-ceramic single crowns (SCs) and fixed dental prostheses (FDPs) supported by ceramic implants.
Materials And Methods: Based on a focused question and customized PICO framework, electronic (Medline/EMBASE/Cochrane) and manual searches for studies reporting the clinical outcomes of all-ceramic SCs and FDPs supported by ceramic implants ≥12 months were performed. The primary outcomes were reconstruction survival and the chipping proportion. The secondary outcomes were implant survival, technical complications, and patient-related outcome measurements. Meta-analyses were performed after 1, 2, and 5 years using random-effect meta-analyses.
Results: Eight of the 1,403 initially screened titles and 55 full texts were included. Five reported on monolithic lithium disilicate (LS2) SCs, one on veneered zirconia SCs, and two on veneered zirconia SCs and FDPs, which reported all on cement-retained reconstructions (mean observation: 12.0-61.0 months). Meta-analyses estimated a 5-year survival rate of 94% (95% confidence interval [CI]: 82%-100%) for overall implant survival. Reconstruction survival proportions after 5 years were: monolithic LS2, 100% (95%CI: 95%-100%); veneered zirconia SCs, 89% (95%CI: 62%-100%); and veneered zirconia FDPs 94% (95%CI: 81%-100%). The chipping proportion after 5 years was: monolithic LS2, 2% (95%CI: 0%-11%); veneered zirconia SCs, 38% (95%CI: 24%-54%); and veneered zirconia FDPs, 57% (95%CI: 38%-76%). Further outcomes were summarized descriptively.
Conclusions: Due to the limited data available, only tendencies could be identified. All-ceramic reconstructions supported by ceramic implants demonstrated promising survival rates after mid-term observation. However, high chipping proportions of veneered zirconia SCs and, particularly, FDPs diminished the overall outcome. Monolithic LS2 demonstrated fewer clinical complications. Monolithic reconstructions could be a valid treatment option for ceramic implants.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9297865 | PMC |
http://dx.doi.org/10.1111/clr.13871 | DOI Listing |
Objective: A 26-year-old woman came for orthodontic treatment to improve her profile with protrusive lips. Diagnosed as bimaxillary protrusion, extraction followed by anterior retraction was indispensable for the case. However, her left upper lateral incisor was absent, the left upper canine had moved mesially and replaced the adjacent incisor, and the original canine location was restored with a long implant, which was in good condition.
View Article and Find Full Text PDFJ Dent
January 2025
Senior Research and Teaching Assistant, Clinic of Reconstructive Dentistry, Center for Dental Medicine, University of Zurich, Plattenstrasse 11, Zurich 8032, Switzerland. Electronic address:
Objectives: A new abutment-free implant connection allows for direct screwing of FDPs on implants to avoid complications caused by cement rests or screw loosening, which may affect to screw torque and load distribution. The objective of this study was to test the initial (Fi) and final failure (Ff) loads and torque changes of abutment-free monolithic zirconia CAD-CAM fixed dental prostheses (FDPs) compared to titanium FDPs on different abutment designs.
Methods: Three-unit screw-retained FDPs (n = 50) on two implants (n = 100) were divided into groups (n = 10) based on the implant-abutment connection and material of the supra-structure: (1) abutment-free monolithic CAD-CAM zirconia FDP (Abut-free-Zr), (2) abutment-free veneered titanium FDPs (Abut-free-Ti), (3) monolithic zirconia FDPs with titanium base abutments (Zr-Ti-Base), (4) monolithic zirconia FDPs on multi-unit abutments (Zr-MU), (5) veneered titanium FDP on multi-unit abutments (Ti-MU).
J Esthet Restor Dent
January 2025
Department of Prosthodontics, Propaedeutics and Dental Materials, School of Dentistry, Christian-Albrechts University at Kiel, Kiel, Germany.
Objective: Investigation of the mechanical properties of occlusal veneers made from zirconia with varying translucency, bonded to different tooth substrates.
Materials And Methods: Sixty-four extracted molars were divided into two groups: preparation within enamel (E) or extending into dentin (D). Veneers were milled from four zirconia ceramics (n = 8): 5Y-TZP (HT), a multilayer of 5 and 3Y-TZP (GT), 3Y-TZP (LT), and 4Y-TZP (MT).
BMC Oral Health
December 2024
Faculty of Odonto-Stomatology, University of Health Sciences, Vietnam National University Ho Chi Minh City, Ho Chi Minh City, Vietnam.
Background: The success of a restoration largely depends on the quality of its fit. This study aimed to investigate the fit quality of monolithic zirconia veneers (MZVs) produced through traditional and digital workflows.
Methods: A typodont maxillary right central incisor was prepared.
Clin Oral Investig
November 2024
Department of Prosthodontics and Materials Science, Leipzig University, Liebigstraße 12, 04103, Leipzig, Germany.
Objectives: This study investigated the influence of prophylactic treatments and thermocycling on the marginal and internal veneering interface (tooth-veneer) as well as on the surface texture of ceramic veneers.
Materials And Methods: A total of 32 extracted human premolars were restored with veneers made of lithium disilicate (LDS) or zirconia-reinforced lithium silicate (ZLS). An artificial aging of the specimens was conducted via five cycles of both thermocycling (5/55°C) and prophylactic treatment (powder air polishing or ultrasonic scaling).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!