For this research, we have considered a case of a man aged 60 years who developed painless fluid accumulation in the implantable cardiac defibrillator (ICD) pocket site. The cardiovascular implantable electronic device initially appeared to be infected, but it was eventually determined that the cause was an allergic reaction, and a novel solution was implemented. For patients with nickel allergies, treatment typically includes avoiding nickel or replacing with gold-plated devices with new leads. Because of the subclavian vein thrombosis, the gold-plated generator was not replaced. ICD generators were covered with antibiotic-coated envelopes while waiting for the replacement. Hypersensitivity to cardiac devices was effectively treated with this technique. By routinely using the envelope, the very rare incidence of device hypersensitivity could further be reduced.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8502759 | PMC |
http://dx.doi.org/10.7759/cureus.17882 | DOI Listing |
J Cardiovasc Electrophysiol
January 2025
Department of Cardiac Electrophysiology and Pacing, Arrhythmia Heart Failure Academy, The Madras Medical Mission, Chennai, Tamil Nadu, India.
Introduction: Permanent implantation of a DF-4 implantable cardiac defibrillator (ICD) lead in the left bundle branch area (LBBA-ICD) is the next paradigm in amalgamating cardiac resynchronization therapy (CRT) and defibrillation. We systematically investigated feasibility/success rate, procedural caveats, and complications associated with a permanent DF-4 LBBA ICD implant and pertinent data at short-term follow-up.
Methods: We prospectively attempted implantation of 7 Fr Durata (Abbott, Chicago, IL, USA) single coil DF-4 ICD lead at the LBBA using a fixed-curve non-deflectable CPS locator delivery sheath.
J Biomed Mater Res B Appl Biomater
February 2025
McGowan Institute for Regenerative Medicine, Pittsburgh, Pennsylvania, USA.
Cardiovascular diseases (CVDs) were responsible for approximately 19 million deaths in 2020, marking an increase of 18.7% since 2010. Biological decellularized patches are common therapeutic solutions for CVD such as cardiac and valve defects.
View Article and Find Full Text PDFMultimed Man Cardiothorac Surg
January 2025
Department of Cardiothoracic Surgery, Faculty of Medicine, Mansoura University Mansoura, Egypt.
The Ross procedure continues to be the best procedure to address unrepairable aortic valve pathology, especially in young adults. The Achilles heel of this procedure has been aortic root dilation and the potential need for a reoperation that may be associated with slightly increased risks in addition to the need for intervention on the pulmonary outflow tract. Modifying the Ross procedure by autograft inclusion inside a Dacron graft seems to have the potential advantage of stabilizing the autograft diameter, which may be associated with improved durability and decrease the need for future intervention.
View Article and Find Full Text PDFJ Cardiovasc Dev Dis
January 2025
Department of Cardiology, University Hospital Galway, Saolta University Healthcare Group, Newcastle Road, H91YR71 Galway, Ireland.
Hospitalisation for acute decompensated heart failure (HF) portends a poor prognosis. Fluid retention manifesting in dyspnoea and oedema are important clinical features of decompensated heart failure and drive hospital admissions. Intracardiac and pulmonary artery pressure (PAP) monitoring can help predict heart failure decompensation, as changes in these haemodynamics occur before clinical congestion manifests.
View Article and Find Full Text PDFJ Cardiovasc Dev Dis
January 2025
Division of Cardiac Surgery, Department of Surgery, University of Alberta, Edmonton, AB T6G 2R3, Canada.
Objectives: Acute type A aortic dissection (ATAAD) is a life-threatening condition that requires emergent surgical intervention. Numerous surgical approaches exist for ATAAD, and controversy remains regarding the optimal arch interventions for ATAAD patients. Aortic Arch Interventions: Approaches to ATAAD repair include hemiarch repair or extended arch repairs, including the hemiarch with a hybrid stent implantation, such as the AMDS hybrid Prosthesis, total arch replacement (TAR), and the use of an elephant trunk and frozen elephant trunk.