Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Continuum robots (CR) have been recently shown capable of micron-scale motion resolutions. Such motions are achieved through equilibrium modulation using for altering either internal preload forces or changing the cross-sectional stiffness along the length of a continuum robot. Previously reported, but unexplained, turning point behavior is modeled using two approaches. An energy minimization approach is first used to explain the source of this behavior. Subsequently, a kinematic model using internal constraints in multi-backbone CRs is used to replicate this turning point behavior. An approach for modeling the micro-motion differential kinematics is presented using experimental data based on the solution of a system of linear matrix equations. This approach provides a closed-form approximation of the empirical micro-motion kinematics and could be easily used for real-time control. A motivating application of image-based biopsy using 3D optical coherence tomography (OCT) is envisioned and demonstrated in this paper. A system integration for generating OCT volumes by sweeping a custom B-mode OCT probe is presented. Results showing high accuracy in obtaining 3D OCT measurements are shown using a commercial OCT probe. Qualitative results using a miniature probe integrated within the robot are also shown. Finally, closed-loop visual servoing using OCT data is demonstrated for guiding a needle into an agar channel. Results of this paper present what we believe is the first embodiment of a continuum robot capable of micro and macro motion control for 3D OCT imaging. This approach can support the development of new technologies for CRs capable of surgical intervention and micro-motion for ultra-precision tasks.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8519402 | PMC |
http://dx.doi.org/10.1109/tmech.2020.3043438 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!