Background: New tetragonal zirconia polycrystal dental implants stabilized with yttria (Y-TZP) have appeared in the implantology market in the form of single piece or two-piece zircona implant system. These new type of implants improve the aesthetical properties compared to conventional commercially pure (c.p.) titanium used for implants, although the long term mechanical behavior of these new implants is not yet well known. In orthopaedics, the application of zirconia as femoral balls presented an important controversial use due to the premature fracture once implanted. Y-TZP dental implants can be affected by hydrothermal degradation and its behavior should be analysed to avoid a premature fracture. The scientific question behind the study is to analyse if the degradation mechanism observed in orthopaedics applications of Y-TZP is similar to that of Y-TZP for dental applications.

Materials And Methods: For this purpose, 30 original Y-TZP dental implants and 42 Y-TZP femoral balls fractured in vivo have been studied. Dental implants were submitted to an accelerated hydrothermal degradation to compare with the femoral balls fractured in vivo. Phase transformation as well as the mechanical behaviour of the degraded samples was studied by X ray diffraction and nanoindentation tests, respectively.

Results: Results have shown that the fracture mechanism of dental implants does not resemble the mechanism observed in orthopaedic samples, presenting a good long-term behaviour.

Conclusion: The results ensure the good performance of zirconia dental implants, because the degradation of the ceramic is very limited and does not affect the mechanical properties.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8520857PMC
http://dx.doi.org/10.1186/s40729-021-00383-2DOI Listing

Publication Analysis

Top Keywords

dental implants
28
femoral balls
16
y-tzp dental
12
implants
10
dental
8
diffraction nanoindentation
8
premature fracture
8
hydrothermal degradation
8
mechanism observed
8
balls fractured
8

Similar Publications

This study aims to evaluate and compare the usability and performance of mixed reality (MR) technology versus conventional methods for preoperative planning of patient-specific reconstruction plates for orbital fractures. A crossover study design was used to compare MR technology with conventional three-dimensional (3D) printing approaches in the planning of maxillofacial traumatology treatments. The primary focus was on user-friendliness and the accuracy of patient-specific reconstruction planning.

View Article and Find Full Text PDF

The effect of the guide hole height on the accuracy of implant placement: an in-vitro study.

J Stomatol Oral Maxillofac Surg

January 2025

School of Dentistry, Chonnam National University, Gwangju, Republic of Korea; Department of Oral & Maxillofacial Surgery, Chonnam National University Hospital, Gwangju, Republic of Korea. Electronic address:

Objective: Guided implant surgery using three-dimensional (3-D) planning software and 3-D printed surgical guides has become a critical tool for enhancing accuracy. This study aims to determine the minimum guide hole height necessary to maintain implant placement accuracy.

Materials And Methods: Ten maxillary models with edentulous areas were created using CT and optical scan data.

View Article and Find Full Text PDF

This study explored a novel modification method for porous polyetheretherketone (PEEK) implants using a biomimetic coating to achieve synergistic enhancement of vascularization and bone regeneration. Inspired by the natural extracellular matrix (ECM) structure (consists of growth factors and matrix proteins), a biomimetic dual-factor coating capable of releasing bone morphogenetic protein-2 (BMP-2) and fibronectin (FN) was coated on the surface of 3D-printed porous PEEK scaffolds using polydopamine (PDA) as a binder. Experiments conducted with MC3T3-E1 cells or HUVECs in co-culture with scaffolds revealed that the biomimetic coating not only synergically promoted cell migration, adhesion and proliferation, but also enhanced angiogenesis and osteogenic differentiation simultaneously in vivo.

View Article and Find Full Text PDF

Load-bearing capacity of an experimental dental implant made of Nb-1Zr.

J Mater Sci Mater Med

January 2025

Clinic of Prosthetic Dentistry and Biomedical Materials Research, Hannover Medical School, Hannover, Germany.

Although implants have undergone a remarkable development over the past decades, modern implants still show complications that make the improvement of materials necessary. The presented study investigates the load-bearing capacity of an experimental dental implant made of a niobium alloy (Nb1Zr) compared to identical implants made of Ti6Al4V using chewing simulation for artificial aging. Eight implants each with an experimental design were manufactured from Nb1Zr and Ti6Al4V.

View Article and Find Full Text PDF

Excess cement and peri-implant disease: A cross-sectional clinical endoscopic study.

J Periodontol

January 2025

Department of Biomedical and Neuromotor Sciences, School of Dentistry - Division of Periodontology and Implantology, Alma Mater Studiorum - University of Bologna, Bologna, Italy.

Background: Crown cementation is a common technique for implant-supported prosthodontics. However, for possible slipping of the cement below the mucosal margin, its thorough removal poses some issues. The objective of this study was to evaluate the presence of submucosal cement residues in patients with peri-implant disease by endoscopic visualization and to investigate the potential correlation between the pathological scenario and the spatial position of cement residues.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!