A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of Au-Pd@UiO-66-on-ZIF-L/CC as a self-supported electrochemical sensor for monitoring of cellular hydrogen peroxide. | LitMetric

Development of Au-Pd@UiO-66-on-ZIF-L/CC as a self-supported electrochemical sensor for monitoring of cellular hydrogen peroxide.

J Mater Chem B

Key Laboratory of Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, P. R. China.

Published: November 2021

Integrating metal-organic frameworks (MOFs) of different components or structures together and exploiting them as electrochemical sensors for electrochemical sensing has aroused great interest. Furthermore, the incorporation of noble metals with MOFs is conducive to the improvement of catalytic performance. In this work, Pd@UiO-66-on-ZIF-L nanomaterials were successfully synthesised onto a self-supported flexible carbon cloth (Pd@UiO-66-on-ZIF-L/CC) through a novel strategy called MOF-on-MOF. Then, Au nanoparticles were electrodeposited onto Pd@UiO-66-on-ZIF-L/CC to obtain Au-Pd@UiO-66-on-ZIF-L/CC, which can serve as an excellent electrocatalyst for the reduction of hydrogen peroxide (HO). The obtained flower-like Pd@UiO-66-on-ZIF-L/CC hybrid MOF changes the structure of the monomeric MOF alone and adds more attachment sites. The synergy of the bimetals greatly improved the catalytic performance of the as-developed sensor. Electrochemical experiment results show that the proposed sensor based on Au-Pd@UiO-66-on-ZIF-L/CC has an extended linear range from 1 μM to 19.6 mM with a sensitivity of 390 μA mM cm, and a low limit of detection (LOD) of 21.2 nM (/ = 3). Moreover, it has good anti-interference, reproducibility, repeatability and excellent stability. Furthermore, the real-time detection of HO secreted from human adenocarcinomic alveolar basal epithelial cells (A549 cells) was achieved by culturing cells on Au-Pd@UiO-66-on-ZIF-L/CC, which indicates the potential of the sensor for applications in cancer pathology. Both the synthesis strategy and the sensor design provide new methods and ideas for the production of ultrasensitive HO electrochemical sensors.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d1tb01120kDOI Listing

Publication Analysis

Top Keywords

hydrogen peroxide
8
electrochemical sensors
8
catalytic performance
8
electrochemical
5
sensor
5
development au-pd@uio-66-on-zif-l/cc
4
au-pd@uio-66-on-zif-l/cc self-supported
4
self-supported electrochemical
4
electrochemical sensor
4
sensor monitoring
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!