This study sought to evaluate the relationship between blood pressure (BP) taken by a new wrist-cuff oscillometric wearable BP monitoring device and left ventricular mass index measured by cardiac magnetic resonance imaging (cMRI-LVMI) in 50 hypertensive patients (mean age 60.5 ± 8.9 years, 92.0% men, 96% treated for hypertension) with regular employment. Participants were asked to self-measure their wearable BPs twice in the morning and evening under a guideline-recommended standardized home BP measurement, and once each at five predetermined times and any additional time points under an ambulatory condition for a maximum of 7 days. In total, 2105 wearable BP measurements (home BP: 747 [morning: 409, evening: 338], ambulatory condition: 1358 [worksite: 942]) were collected over 5.5 ± 1.2 days. The average of all wearable systolic BP (SBP) readings (129.8 ± 11.0 mmHg) was weakly correlated with cMRI-LVMI (r = 0.265, p = 0.063). Morning home wearable SBP average (128.5 ± 13.8 mmHg) was significantly correlated with cMRI-LVMI (r = 0.378, p = 0.013), but ambulatory wearable SBP average (132.5 ± 12.7 mmHg) was not (r = 0.215, p = 0.135). The averages of the highest three values of all wearable SBPs (153.3 ± 13.9 mmHg) and ambulatory wearable SBPs (152.9 ± 13.9 mmHg) were 16 mmHg higher than that of the morning home wearable SBPs (137.0 ± 15.9 mmHg). Those peak values were significantly correlated with cMRI-LVMI (r = 0.320, p = 0.023; r = 0.310, p = 0.029; r = 0.451, p = 0.002, respectively). In conclusion, an increased number of wearable BP measurements, which could detect individual peak BP, might add to the clinical value of these measurements as a complement to the guideline-recommended home BP measurements, but further studies are needed to confirm these findings.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1038/s41440-021-00758-3 | DOI Listing |
Front Cardiovasc Med
December 2024
Department of Vascular Surgery, The Second Affiliated Hospital, Hengyang Medical School, University of South China, Hengyang, Hunan, China.
Background: Percutaneous mechanical thrombectomy (PMT) is increasingly used in the treatment of intermediate and high-risk acute pulmonary embolism (PE), and the treatment of high-risk PE with the aid of veno-arterial extracorporeal membrane oxygenation (VA-ECMO) has also been reported. However, there are few reports of VA-ECOM-assisted PMT in the treatment of high-risk PE. The purpose of this study is to summarize the data of 11 patients with high-risk PE treated with VA-ECMO assisted PMT, and propose feasible treatment methods for such patients.
View Article and Find Full Text PDFFront Cardiovasc Med
December 2024
Department of Midwifery, College of Health Sciences, Addis Ababa University, Addis Ababa, Ethiopia.
Introduction: Based on office blood pressure (BP) values, hypertension is categorized into three stages: stage 1 (140-159/90-99 mmHg), stage 2 (160-179/100-109 mmHg), and stage 3 (≥180/≥110 mmHg). Malignant hypertension (MHT) is characterized by extreme BP elevation (systolic blood pressure above 200 mmHg and diastolic blood pressure above 130 mmHg) and acute microvascular damage affecting various organs, particularly the retinas, brain, and kidneys.
Objectives: The pathogenesis, predisposing variables, therapy, and preventive strategies for MHT were examined in this review.
J Biomed Opt
June 2024
Food and Drug Administration, Center for Devices and Radiological Health, Silver Spring, Maryland, United States.
Significance: Pulse oximeter measurements are commonly relied upon for managing patient care and thus often require human testing before they can be legally marketed. Recent clinical studies have also identified disparities in their measurement of blood oxygen saturation by race or skin pigmentation.
Aim: The development of a reliable bench-top performance test method based on tissue-simulating phantoms has the potential to facilitate pre-market assessment and the development of more accurate and equitable devices.
J Pain Res
January 2025
Department of Anesthesiology, Beijing Chao-Yang Hospital, Capital Medical University, Beijing, 100043, People's Republic of China.
Objective: To evaluate the clinical efficacy and safety of ultrasound-guided rectus sheath block (RSB) in laparoscopic umbilical hernia repair with intraperitoneal onlay mesh (IPOM).
Methods: A total of 139 patients scheduled for laparoscopic umbilical hernia repair with IPOM were selected and randomly assigned to either the group receiving general anesthesia combined with bilateral rectus sheath block (Group GR, 71 patients) or the group receiving general anesthesia alone (Group G, 68 patients). We monitored the patients' heart rate (HR) and mean arterial pressure (MAP) at four time points: before anesthesia induction (T1), at the start of surgery (T2), during mesh fixation (T3), and upon removal of the laryngeal mask (T4).
Cureus
December 2024
Internal Medicine, Unidade Local de Saúde de Trás-os-Montes e Alto Douro, Chaves, PRT.
Fever is a classic reason for hospital visits, sometimes requiring admission. Its etiologies are numerous, ranging from simple and relatively common conditions to rare and complex pathologies, for which the differential diagnosis can present a true challenge for internists. A 78-year-old healthy female is referred to the emergency department due to marked fatigue for the past four months, with no other symptoms.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!