A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Use of the Off-The-Shelf Pre-Cannulated E-Nside Endograft to Overcome Anatomical Challenges in Urgent Complex Endovascular Aortic Repair. | LitMetric

Use of the Off-The-Shelf Pre-Cannulated E-Nside Endograft to Overcome Anatomical Challenges in Urgent Complex Endovascular Aortic Repair.

Ann Vasc Surg

Department of Vascular Surgery, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom.

Published: February 2022

Treatment options for large or symptomatic complex aortic aneurysms that require urgent intervention remain limited. Patient factors and comorbidities often make open surgery unappealing, leading to increasing interest in endovascular solutions that can be employed in the urgent setting, such as off-the-shelf endografts. The E-nside (Jotec GmbH, Hechingen, Germany) is a new off-the-shelf endograft with 4 pre-cannulated inner branches that has recently become available in Europe. We report the urgent treatment of 2 large complex aortic aneurysms using this device and discuss the benefits of this new technology. The E-nside off-the-shelf endograft with inner branches is a useful addition to our treatment options for complex aortic aneurysms, particularly those with a narrow aortic lumen. Pre-cannulation of branches provides consistent access to the branches and a readily available option for establishment of a through and through wire for added stability during cannulation and bridging stent-grafts placement. The design of inner branches provides flexibility during deployment of the endograft and cannulation of the target vessels in varied, challenging anatomies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.avsg.2021.07.045DOI Listing

Publication Analysis

Top Keywords

complex aortic
12
aortic aneurysms
12
inner branches
12
treatment options
8
off-the-shelf endograft
8
aortic
5
branches
5
off-the-shelf
4
off-the-shelf pre-cannulated
4
pre-cannulated e-nside
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!