Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: The aim of this study was to assess the feasibility, performance, and complications of a non-surgical, minimally-invasive procedure of deep contraceptive implant removal under continuous ultrasound guidance.
Methods: The ultrasound-guided procedure consisted of local anesthesia using lidocaine chlorhydrate 1% (10 mg/mL) with a 21-G needle, followed by hydrodissection using NaCl 0.9% (9 mg/mL) and implant extraction using a Hartmann grasping microforceps. The parameters studied were the implant localization, success and complication rates, pain throughout the intervention, volumes of lidocaïne and NaCl used, duration of the procedure, and size of the incision. Between November 2019 and January 2021, 45 patients were referred to the musculoskeletal radiology department for ultrasound-guided removal of a deep contraceptive implant and were all retrospectively included.
Results: All implants were successfully removed en bloc (100%). The mean incision size was 2.7 ± 0.5 mm. The mean duration of the extraction procedure was 7.7 ± 6.3 min. There were no major complications (infection, nerve, or vessel damage). As a minor complication, 21 patients (46.7%) reported a benign superficial skin ecchymosis at the puncture site, spontaneously regressing in less than 1 week. The procedure was very well-tolerated, with low pain rating throughout (1.0 ± 1.5/10 during implant extraction).
Conclusions: Minimally invasive removal of deep contraceptive implants under continuous ultrasound guidance alone is feasible, effective, and safe. In the present cohort, all implants were successfully removed, whatever the location, with short procedural time, small incision size, low pain levels, and no significant complications. This procedure could become a gold standard in this indication.
Key Points: • Minimally invasive removal of deep contraceptive implants under continuous ultrasound guidance alone is feasible, which led to a success rate of 100% whatever the location (even close to neurovascular structures), with only a small skin incision (2.7 ± 0.5 mm). • The procedure was safe, quick, without any major complications, and very well tolerated in terms of pain. • This minimally invasive ultrasound-guided procedure could become the future gold standard for the removal of deep contraceptive implants, as an alternative to surgical extraction, even for implants in difficult locations such as subfascial ones or those close to neurovascular structures.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8831252 | PMC |
http://dx.doi.org/10.1007/s00330-021-08263-4 | DOI Listing |