Unlabelled: The use of low-profile dorsal and volar locking plates for distal radial fracture surgery has improved results and lowered the complication rate compared with older plate designs. The purpose of the present randomized controlled trial was to compare patient-reported outcomes as well as radiographic and functional results between patients who underwent stabilization with a volar locking plate or a dorsal locking nail-plate for the treatment of dorsally displaced unstable extra-articular distal radial fractures.
Methods: One hundred and twenty patients ≥55 years of age were randomized to surgery with either a volar locking plate or a dorsal locking nail-plate and were assessed at 2 weeks, 6 weeks, 3 months, 6 months, and 1 year. The primary outcome was the abbreviated version of the Disabilities of the Arm, Shoulder and Hand (QuickDASH) score. Secondary outcomes were the Patient-Rated Wrist Evaluation (PRWE), EuroQol 5 Dimensions (EQ-5D) index and visual analog scale (VAS), range of motion, grip strength, radiographic measurements, and complication rate.
Results: The median age was 66 years (range, 55 to 88 years). The rate of follow-up was 97%. There was no clinically important difference between the groups at any point during follow-up. Patients in the volar locking plate group had better mean QuickDASH scores at 6 weeks, 6 months, and 1 year. However, the differences were small (5.8 vs. 11.3 points at 1 year; mean difference, -5.5 points [95% confidence interval (CI), -9.9 to 1.2]; p = 0.014), which is lower than any proposed minimum clinically important difference (MCID). The difference in PRWE scores was also lower than the MCID (1.0 vs. 3.5 at 1 year; mean difference, -2.5 [95% CI, -4.4 to 0.6]; p = 0.012). The dorsal locking nail-plate group had slightly better restoration of volar tilt (p = 0.011). EQ-5D index, EQ-5D VAS, range of motion, grip strength, and complication rates were similar.
Conclusions: We found no clinically relevant difference between the volar locking plate and dorsal locking nail-plate groups after 1 year or in the time period up to 1 year. A dorsal locking nail-plate can therefore be an alternative method for the treatment of these unstable fractures or in cases in which a dorsal approach is preferable over a volar approach.
Level Of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8509916 | PMC |
http://dx.doi.org/10.2106/JBJS.OA.21.00068 | DOI Listing |
Tech Hand Up Extrem Surg
January 2025
Department of Orthopaedics, University of Miami, Miller School of Medicine, Miami, FL.
There are many approaches to the wrist both volar and dorsal, depending on the injury at hand. The design of the volar locking plate has created a rise in distal radius fractures being treated using a volar FCR approach and its modifications. It does, however, have limitations in visualization of the volar ulnar corner of the radius.
View Article and Find Full Text PDFJ Hand Surg Eur Vol
January 2025
Department of Orthopedics, E-Da Hospital, I-Shou University/School of Medicine, College of Medicine, I-Shou University, Kaohsiung, Taiwan.
Treatment of distal radial fractures that include small anterior rim fragments can be difficult. We retrospectively reviewed 19 patients in whom an anterior rim plate with locking screws was used. After a median follow-up of 18 months (range 6-32; interquartile range (IQR) 14, 26), the median wrist flexion and extension arc was 70° (range 50-80; IQR 60, 70), the median grip strength was 80% of the contralateral side (range 52-104; IQR 77, 88), the median visual analogue scale score for pain was 0 (range 0-5; IQR 0, 1), the median disabilities of the arm, shoulder and hand score was 2 (range 0-59; IQR 0, 11) and the median modified Mayo wrist score was 80 (range 35-100; IQR 75, 85).
View Article and Find Full Text PDFAnn Plast Surg
December 2024
Department of Orthopaedic Surgery, Duson Hospital, Ansan, Korea.
Background: Extra-articular but severely comminuted distal basal fractures of the proximal phalanx (PP) are rarely reported. Therefore, the aim of this study was to achieve proper union and desirable outcomes using low-profile locking plates/screws. We introduced our own surgical approach and reported the clinical/radiographic outcomes via retrospective case series.
View Article and Find Full Text PDFOrthop Traumatol Surg Res
December 2024
Service de Chirurgie Orthopédique et Traumatologique, Hôpital de la Cavale Blanche, Boulevard Tanguy Prigent, Brest 29200, France; Université de Bretagne Occidentale, UBO, Brest 29200, France; LaTIM, INSERM, UMR 1101, SFR IBSAM, Avenue Foch, Brest 29200, France. Electronic address:
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!