Background: Ceramic-on-ceramic bearings permit the use of large femoral head size while maintaining a favorable effect on wear rates. However, because of increased device rigidity, periprosthetic bone quality could be negatively affected due to stress shielding. The purpose of this study is to assess pelvic periprosthetic bone remodeling around a monoblock ceramic-on-ceramic acetabular component compared to that around a conventional modular metal-on-polyethylene device.

Methods: Participants were randomized to receive hip replacement using either a porous-coated, modular metal-on-polyethylene acetabular component (n = 46) or a hydroxyapatite and titanium-coated monoblock shell with an integrated ceramic-on-ceramic bearing (n = 40). Radiographic assessments were completed preoperatively and postoperatively, and measurements of bone mineral density (BMD) using dual-energy X-ray absorptiometry with region free analysis were performed postoperatively and over 2-years of follow-up.

Results: There was no significant difference in BMD between the 2 groups at baseline or over the following 2 years. At follow-up, complete shell-to-bone contact without a radiolucent line was observed in 26 (67%) of the modular devices and in 37 (93%) of monoblock (P < .001). The modular device was an independent predictor of radiolucent lines (odds ratio 19.1, P = .007). No cases underwent revision surgery for acetabular loosening.

Conclusion: Both the porous-coated modular and hydroxyapatite-coated monoblock acetabular components showed successful clinical results at short-term follow-up with no difference in pixel-level BMD. Using a large head monoblock device does not appear to be associated with an adverse effect on the local bone environment when compared to a modular device. NCT: NCT01558752.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2021.08.033DOI Listing

Publication Analysis

Top Keywords

acetabular component
12
monoblock acetabular
8
conventional modular
8
periprosthetic bone
8
modular metal-on-polyethylene
8
porous-coated modular
8
modular device
8
modular
7
monoblock
6
bone
5

Similar Publications

Acetabular orientation, pelvic shape, and the evolution of hominin bipedality.

J Hum Evol

January 2025

Department of Pathology and Anatomical Sciences, University of Missouri, Columbia, MO 65212, USA.

Hominin pelvic form differs dramatically from that of other primates by having more laterally facing iliac blades, a wider sacrum, and a larger, transversely broad pelvic inlet. The orientation of the acetabulum may also differ, plausibly related to differences in load transmission during upright posture and habitual bipedal locomotion, which may, in turn, affect overall pelvic geometry. We compared acetabular orientation in humans, a phylogenetically broad sample of extant anthropoid primates, and fossil hominins including Australopithecus afarensis (A.

View Article and Find Full Text PDF

Background: Total Hip Arthroplasty (THA) is a transformative surgical intervention for hip joint disorders, necessitating meticulous preoperative planning for optimal outcomes. With the emergence of Artificial Intelligence (AI), preoperative planning paradigms have evolved, leveraging AI algorithms for enhanced decision support and imaging analysis. This systematic review aims to comprehensively evaluate the role of AI in THA preoperative planning, synthesizing evidence from studies exploring various AI techniques and their applications.

View Article and Find Full Text PDF

Background: Survival at 25 years' follow-up for total hip arthroplasty (THA) has been reported at 5%-77%, with hydroxyapatite (HA) coating, due to its osteo-conductive properties, used to enhance implant fixation and survival. The progressive increase in life expectancy raises doubts regarding HA-coated THA survival and THA revision surgery risk. The aim of our study was to retrospectively analyse survival for primary uncemented fully HA-coated THA after 28 years' follow-up.

View Article and Find Full Text PDF

Patient-specific flanged acetabular components are utilized to treat failed total hip arthroplasties with severe acetabular defects. We previously developed and published a finite element model that investigated the impact of hip joint center lateralization on construct biomechanics during gait conditions. This model consisted of a patient-specific implant designed to address a superior-medial defect created in a standard pelvic geometry.

View Article and Find Full Text PDF

Background: Proper positioning of a total hip arthroplasty (THA) plays a crucial role in the success and long-term survivorship of the implant. Cup positioning within the Lewinnek Safe Zone (LSZ) does not, however, avoid implant dislocation. Thus, the concept of a functional cup position has been introduced.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!