Pulmonic and sub-pulmonic valve endocarditis are rarely encountered in clinical practice. We present the first case of isolated sub-pulmonic endocarditis. A 30-year-old man with a history of mechanical aortic valve presented to the emergency department with multiple complaints including nausea, vomiting, body aches, and fevers. The patient underwent surgical resection for sub-aortic stenosis followed by a modified Konno procedure later in life. A modified basal short-axis view on the trans-thoracic echocardiogram revealed a sub-pulmonic mobile structure highly suggestive of infective endocarditis. Blood cultures grew methicillin-sensitive  within 24 hours. Higher oxygen demand prompted chest imaging, chest CT showed the development of bilateral airspace consolidation, suggestive of pneumonia. After treatment with extended intravenous antibiotics, follow-up echocardiogram four months later showed no identifiable sub-pulmonic vegetation. This case describes a situation where clinicians may suspect infective endocarditis in a typical location such as a mechanical aortic valve. However, in patients who develop pneumonia, infective endocarditis of the right heart should be suspected. The pulmonic valve and sub-pulmonic ridge are often difficult to image given their anatomical location, a modified basal short-axis view on trans-thoracic echocardiogram can better image these structures.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8483447PMC
http://dx.doi.org/10.7759/cureus.17594DOI Listing

Publication Analysis

Top Keywords

mechanical aortic
12
isolated sub-pulmonic
8
sub-pulmonic valve
8
valve endocarditis
8
konno procedure
8
aortic valve
8
modified basal
8
basal short-axis
8
short-axis view
8
view trans-thoracic
8

Similar Publications

Background: Transcatheter closure of percutaneous paravalvular leak (PVL) is a technically challenging procedure, especially after surgical mechanical valve replacements (SMVR), as the risk of interference with the prosthetic valve discs and the complex interventional techniques required for mitral PVL closure. Our study was designed to review the results with transcatheter closure of PVL after SMVR.

Methods: From January 2018 through December 2023, a total of 64 patients with PVL after SMVR underwent transcatheter closure with the help of preoperative 3-dimensional printing model and simulator for image evaluation.

View Article and Find Full Text PDF

Analysis of the haemodynamic changes caused by surgical and transcatheter aortic valve replacements by means fluid-structure interaction simulations.

Comput Biol Med

January 2025

UCL Mechanical Engineering, University College London, UK; Ri.MED Foundation, Palermo, Italy; University of Palermo, Department of Engineering, Palermo, Italy. Electronic address:

Aortic valve replacements, both surgical and transcatheter, are nowadays widely employed treatments. Although clinically effective, these procedures are correlated with potentially severe clinical complications which can be associated with the non-physiological haemodynamics that they establish. In this work, the fluid dynamics changes produced by surgical and transcatheter aortic valve replacements are analysed and compared with an ideal healthy native valve configuration, employing advanced fluid-structure interaction (FSI) simulations.

View Article and Find Full Text PDF

Arterial compliance (AC) is an important cardiovascular parameter characterizing mechanical properties of arteries. AC is significantly influenced by arterial wall structure and vasomotion, and it markedly influences cardiac load. A new method, based on a two-element Windkessel model, has been recently proposed for estimating AC as the ratio of the time constant T of the diastolic blood pressure decay and peripheral vascular resistance derived from clinically available stroke volume measurements and selected peripheral blood pressure parameters which are less prone to peripheral distortions.

View Article and Find Full Text PDF

Age, creatinine, and ejection fraction score is a risk factor for acute kidney injury after surgical aortic valve replacement.

Ren Fail

December 2025

Center for Cardiac Intensive Care, Beijing Anzhen Hospital, Capital Medical University, Beijing Institute of Heart, Lung and Blood Vessel Diseases, Beijing, China.

Background: The incidence of acute kidney injury (AKI) increases after surgical aortic valve replacement (SAVR). This study aimed to characterize the risk factors of AKI after SAVR.

Methods And Results: We conducted a retrospective registry study based on data from 299 consecutive patients undergoing SAVR.

View Article and Find Full Text PDF

Aortic valve leaflet assessment to inform novel bioinspired materials: Understanding the impact of collagen fibres on the tissue's mechanical behaviour.

J Mech Behav Biomed Mater

December 2024

Trinity Centre for Biomedical Engineering, Trinity Biomedical Sciences Institute, Trinity College Dublin, 2, Dublin, Ireland; Discipline of Mechanical, Manufacturing, and Biomedical Engineering, School of Engineering, Trinity College Dublin, 2, Dublin, Ireland; Advanced Materials and Bioengineering Research Centre (AMBER), Trinity College Dublin, Ireland. Electronic address:

Aortic stenosis is a prevalent disease that is treated with either mechanical or bioprosthetic valve replacement devices. However, these implants can experience problems with either functionality in the case of mechanical valves or long-term durability in the case of bioprosthetic valves. To enhance next generation prosthetic valves, such as biomimetic polymeric valves, an improved understanding of the native aortic valve leaflet structure and mechanical response is required to provide much needed benchmarks for future device development.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!