A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Performance of Reinforced Concrete Beams Strengthened with Carbon Fiber Reinforced Polymer Strips. | LitMetric

Performance of Reinforced Concrete Beams Strengthened with Carbon Fiber Reinforced Polymer Strips.

Materials (Basel)

Department of Architectural Engineering, Inha University, Incheon 22212, Korea.

Published: October 2021

Carbon fiber reinforced polymers (CFRP) have shown considerable potential in the repair and rehabilitation of deficient reinforced concrete (RC) structures. To date, several CFRP strengthening schemes have been studied and employed practically. In particular, strengthening of shear damaged RC members with CFRP materials has received much attention as an effective repair and strengthening approach. Most existing studies on strengthening shear-deficient RC members have used unidirectional CFRP strips. Recent studies on strengthened T-beams demonstrated that a bidirectional CFRP layout was more effective than a unidirectional layout. As such studies are limited, in this study, the feasibility of bidirectional CFRP layouts for the shear strengthening of rectangular RC beams was experimentally evaluated. Bidirectional layout details with CFRP anchors as well as rehabilitation timing were considered and investigated. The test results showed that the members with a bidirectional CFRP layout carried less shear strength capacity than those with unidirectional layouts for the same quantity of CFRP material. Nevertheless, the bidirectional CFRP layout allowed for a uniformly distributed stirrup strain compared to the unidirectional CFRP layout at the same load level, which increased the efficiency of the transverse reinforcement. Additionally, the shear contribution of CFRP material according to the CFRP strengthening timing was verified.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8510033PMC
http://dx.doi.org/10.3390/ma14195866DOI Listing

Publication Analysis

Top Keywords

bidirectional cfrp
16
cfrp layout
16
cfrp
13
reinforced concrete
8
carbon fiber
8
fiber reinforced
8
cfrp strengthening
8
unidirectional cfrp
8
cfrp material
8
strengthening
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!