An online method involving transient electrokinetic dosing and ITP with neutralization reaction boundary (NRB) and/or carrier ampholyte-free isoelectric focusing (CAF IEF) was developed for the preconcentration, preseparation, and analytical determination of glyphosate in aqueous samples containing low concentrations of the analyte of interest. Various parameters were investigated in the framework of an optimization study with the aim of achieving the maximum concentration limit of detection (cLOD) decrease in minimum time. The proposed method used CAF IEF and/or ITP with NRB. The sample was dosed to the column on the stationary reaction boundary (CAF IEF) and/or moving reaction boundary (ITP with NRB), whereat a sharp pH step exists. Here, charge reversal was due to the ampholytes, and/or acid accumulation occurred because of charge loss. Similarly, the accumulated sample was mobilized with TE and analyzed using classical ITP in the second analytical column. Glyphosate (GLY), the analyte of interest, was chosen as a model substance for ITP with NRB and preconcentration as well as focusing preconcentration and CAF IEF using the asymmetric purpose-built NRB. On one side of the asymmetric boundary was the zone of acidic pH; while the opposite side comprised a neutral/basic non-conductive zone of the ampholyte-in this case, GLY. Such an arrangement enables the use of a lower pH on the acidic side, which allows the focusing of strongly acidic ampholytes and the accumulation of weak acids. The electrolyte composition and the dosing time were optimized, and a 14-fold accumulation was achieved in 25 min compared to that by classical ITP and a 180-fold accumulation was achieved through CAF IEF and preconcentration with a glyphosate sample. Both methods are simple and can be conducted using all commercial ITP systems.

Download full-text PDF

Source
http://dx.doi.org/10.1002/elps.202000398DOI Listing

Publication Analysis

Top Keywords

caf ief
20
reaction boundary
16
itp nrb
12
analyte interest
8
ief and/or
8
classical itp
8
accumulation achieved
8
itp
7
boundary
5
nrb
5

Similar Publications

An online method involving transient electrokinetic dosing and ITP with neutralization reaction boundary (NRB) and/or carrier ampholyte-free isoelectric focusing (CAF IEF) was developed for the preconcentration, preseparation, and analytical determination of glyphosate in aqueous samples containing low concentrations of the analyte of interest. Various parameters were investigated in the framework of an optimization study with the aim of achieving the maximum concentration limit of detection (cLOD) decrease in minimum time. The proposed method used CAF IEF and/or ITP with NRB.

View Article and Find Full Text PDF

The use of carrier ampholyte-free IEF (CAF-IEF) with ITP mobilization and conductivity detection in ITP mode for preconcentration and analysis of amino acids is demonstrated. The analytical procedure consists of three subsequent steps. In the first step, amino acids are continuously dosed from an infinite volume reservoir by electromigration to the column, where a sharp, stationary neutralization reaction boundary (NRB) is created in between acidic and basic primary electrolyte.

View Article and Find Full Text PDF

Mass spectrometry is being increasingly used for analysis of proteome complex samples. Sample preparation is often necessary to remove matrix interferences and to concentrate analytes prior to MS measurement. A useful method for this purpose is Carrier Ampholyte Free-Isoelectric Focusing (CAF-IEF).

View Article and Find Full Text PDF

The applicability of carrier ampholyte-free isoelectric focusing (CAF-IEF) for analyses of ampholytes is demonstrated. The suggested method is based on the principle of both side regulated ionic matrix in CAF-IEF. A sharp step of pH is created in the column filled with a sample dissolved in a background electrolyte by influence of current and solvolytic fluxes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!