Aims: To investigate medication dose calculation errors and other numeracy mishaps in hospitals and examine mechanisms and enablers which lead to such errors.
Design: A retrospective study using descriptive statistics and thematic analysis of the nature and enablers of reported incidents.
Methods: Medication dose calculation errors and other numeracy mishaps were identified from medication-related incidents reported to the Norwegian Incident Reporting System in 2016 and 2017. The main outcome measures were medications and medication classes involved, severity of harm, outcome, and error enablers.
Results: In total, we identified 100 numeracy errors, of which most involved intravenous administration route (n = 70). Analgesics were the most commonly reported drug class and morphine was the most common individual medication. Overall, 78 incidents described patient harm. Frequent mechanisms were 10- or 100-fold errors, mixing up units, and incorrect strength/rate entered into infusion pumps. The most frequent error enablers were: double check omitted or deviated (n = 40), lack of safety barriers to intercept prescribing errors (n = 25), and emergency/stress (n = 21).
Conclusion: Numeracy errors due to lack of or improper safeguards occurred during all medication management stages. Dose miscalculation after dilution of intravenous solutions, infusion pump programming, and double-checking were identified as unsafe practices. We discuss measures to prevent future calculation and numeracy errors.
Impact: Our analysis of medication dose calculation errors and other numeracy mishaps demonstrates the need for improving safety steps and increase standardization for medication management procedures. We discuss organizational, technological, and educational measures to prevent harm from numeracy errors.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/jan.15072 | DOI Listing |
Eur J Radiol
January 2025
Department of Radiology Children's Hospital of Chongqing Medical University, National Clinical Research Center for Child Health and Disorders, Ministry of Education Key Laboratory of Child Development and Disorders, Chongqing Key Laboratory of Child Neurodevelopment and Cognitive Disorders, China. Electronic address:
Objective: To explore the clinical value of combining split-bolus contrast injection with dual-energy CT(DECT) scanning technology in pediatric computed tomography urography (CTU) imaging.
Methods: A total of 128 children aged 0-17 years were prospectively selected and randomly assigned to three groups: A, B, and C. For Group A, a high-pitch flash mode was employed, where a single bolus of contrast agent was followed by four-phase scanning (noncontrast, cortex, medulla, and excretory phases).
J Occup Environ Hyg
January 2025
Institute of Physical Factors and Occupational Health, Guangdong Province Hospital for Occupational Disease Prevention and Treatment, Guangzhou, Guangdong Province, China.
The noise exposure levels of workers wearing hearing protective devices (HPDs) depend on ambient noise and the protective effect of hearing protectors. This cross-sectional study aimed to adjust for cumulative noise exposure (CNE) based on the effective protection of hearing protection devices and explore the dose-response relationship between noise-induced hearing loss (NIHL) and adjusted cumulative noise exposure. A questionnaire was used to acquire the basic characteristics and occupational information of noise-exposed workers.
View Article and Find Full Text PDFThe prognosis for patients with acute promyelocytic leukemia (APL) has improved dramatically since the introduction of all-trans retinoic acid (ATRA) and intravenous arsenic trioxide (ATO). However, ATO administration requires daily infusions over several months, representing an onerous burden for hospitals and patients. We evaluated the bioavailability of a novel encapsulated oral ATO formulation in APL patients in first complete remission during standard-of-care consolidation.
View Article and Find Full Text PDFHealth Phys
January 2025
Department of Radiation Oncology & Medical Physics, Inova Health Systems, Fairfax, Virginia.
Occupational radiation dosimeters that return high readings cannot always be explained by circumstances in the workplace. For this experiment, a series of optically stimulated luminescence (OSL) dosimeters were brought to airports to estimate the radiation dose OSLs would receive should a worker accidentally bring their dosimeter with them during travel. The OSLs returned readings between 0.
View Article and Find Full Text PDFMenopause
January 2025
From the Department of General Practice, Monash University, Melbourne, Australia.
Objective: The aim of this study was to explore the meanings and experiences of menopause for trans and gender diverse (TGD) people and how menopause affects clinical practice.
Methods: For this qualitative study in 2021-2022, a scoping literature review informed interview schedule development. Following email invitations, online semi-structured interviews were conducted in March-April 2021 in Australia with three prominent TGD community leaders (trans male, trans female, nonbinary person) and three experienced medical practitioners (general practitioner, endocrinologist, psychiatrist), which were audio-recorded and transcribed.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!