Purpose: Recently, two-dimensional-to-three-dimensional (2D-3D) deformable registration has been applied to deform liver tumor contours from prior reference images onto estimated cone-beam computed tomography (CBCT) target images to automate on-board tumor localizations. Biomechanical modeling has also been introduced to fine-tune the intra-liver deformation-vector-fields (DVFs) solved by 2D-3D deformable registration, especially at low-contrast regions, using tissue elasticity information and liver boundary DVFs. However, the caudal liver boundary shows low contrast from surrounding tissues in the cone-beam projections, which degrades the accuracy of the intensity-based 2D-3D deformable registration there and results in less accurate boundary conditions for biomechanical modeling. We developed a deep-learning (DL)-based method to optimize the liver boundary DVFs after 2D-3D deformable registration to further improve the accuracy of subsequent biomechanical modeling and liver tumor localization.

Methods: The DL-based network was built based on the U-Net architecture. The network was trained in a supervised fashion to learn motion correlation between cranial and caudal liver boundaries to optimize the liver boundary DVFs. Inputs of the network had three channels, and each channel featured the 3D DVFs estimated by the 2D-3D deformable registration along one Cartesian direction (x, y, z). To incorporate patient-specific liver boundary information into the DVFs, the DVFs were masked by a liver boundary ring structure generated from the liver contour of the prior reference image. The network outputs were the optimized DVFs along the liver boundary with higher accuracy. From these optimized DVFs, boundary conditions were extracted for biomechanical modeling to further optimize the solution of intra-liver tumor motion. We evaluated the method using 34 liver cancer patient cases, with 24 for training and 10 for testing. We evaluated and compared the performance of three methods: 2D-3D deformable registration, 2D-3D-Bio (2D-3D deformable registration with biomechanical modeling), and DL-Bio (DL model prediction with biomechanical modeling). The tumor localization errors were quantified through calculating the center-of-mass-errors (COMEs), DICE coefficients, and Hausdorff distance between deformed liver tumor contours and manually segmented "gold-standard" contours.

Results: The predicted DVFs by the DL model showed improved accuracy at the liver boundary, which translated into more accurate liver tumor localizations through biomechanical modeling. On a total of 90 evaluated images and tumor contours, the average (± sd) liver tumor COMEs of the 2D-3D, 2D-3D-Bio, and DL-Bio techniques were 4.7 ± 1.9 mm, 2.9 ± 1.0 mm, and 1.7 ± 0.4 mm. The corresponding average (± sd) DICE coefficients were 0.60 ± 0.12, 0.71 ± 0.07, and 0.78 ± 0.03; and the average (± sd) Hausdorff distances were 7.0 ± 2.6 mm, 5.4 ± 1.5 mm, and 4.5 ± 1.3 mm, respectively.

Conclusion: DL-Bio solves a general correlation model to improve the accuracy of the DVFs at the liver boundary. With improved boundary conditions, the accuracy of biomechanical modeling can be further increased for accurate intra-liver low-contrast tumor localization.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8678353PMC
http://dx.doi.org/10.1002/mp.15275DOI Listing

Publication Analysis

Top Keywords

liver boundary
40
biomechanical modeling
36
2d-3d deformable
28
deformable registration
28
liver tumor
24
liver
18
boundary dvfs
16
boundary
13
tumor localization
12
tumor contours
12

Similar Publications

Purpose: This study aimed to evaluate the efficacy of indocyanine green (ICG)-fluorescence imaging for the identification of hepatic boundaries during liver resection and its advantages in surgical outcomes over conventional methods.

Methods: This prospective, exploratory, single-arm clinical trial included 47 patients with liver tumors who underwent liver resection using ICG-fluorescence imaging (ICG-LR) between 2019 and 2020. The primary outcome measure was the successful identification of hepatic boundaries during liver resection, from the perspective of both the hepatic surface and intrahepatic boundary, using ICG-fluorescence imaging.

View Article and Find Full Text PDF

Current advance in comprehensive management of hilar cholangiocarcinoma and navigation in surgery: non-systematic reviews.

Int J Surg

December 2024

Hepatobiliary Surgery Department, National Cancer Center, National Clinical Research Center for Cancer, Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.

Hilar Cholangiocarcinoma (h-CCA) originates from the epithelial cells, which characters as longitudinal growth along the bile ducts and invasion of peripheral vascular nerves. Due to the tumours insidious progression and usually become advanced stage disease at presentation, patients' mortality could parallel incidence rates. For patients who are not amenable to resection, systemic therapy and palliative treatment become the way to go.

View Article and Find Full Text PDF

The surgical management of hepatic metastases from colorectal cancer may range from segmental resections to major or extended hepatectomies. The aim is to achieve complete removal of metastatic lesions while preserving adequate liver function. We present the case of a 42-year-old male patient with a history of glucose intolerance who presented with altered bowel movements and abdominal pain.

View Article and Find Full Text PDF

Background: Conventional right hepatectomy typically involves resection of the right hemiliver, often including partial removal of the caudate lobe. However, recent advancements, particularly in indocyanine green (ICG) fluorescence imaging, have allowed for more accurate identification of anatomical boundaries between liver segments. In this context, we present a refined technique for real anatomical right hepatectomy that preserves the caudate lobe, offering enhanced surgical precision and several distinct advantages over traditional methods.

View Article and Find Full Text PDF

Computational exploration of injection strategies for improving medicine distribution in the liver.

Comput Biol Med

December 2024

Faculty of Chemical & Petroleum Engineering, University of Tabriz, Tabriz, Iran. Electronic address:

Background And Objectives: The liver, a vital metabolic organ, is always susceptible to various diseases that ultimately lead to fibrosis, cirrhosis, acute liver failure, chronic liver failure, and even cancer. Optimal and specific medicine delivery in various diseases, hepatectomy, shunt placement, and other surgical interventions to reduce liver damage, transplantation, optimal preservation, and revival of the donated organ all rely on a complete understanding of perfusion and mass transfer in the liver. This study aims to simulate the computational fluid dynamics of perfusion and the temporal-spatial distribution of a medicine in a healthy liver to evaluate the hemodynamic characteristics of flow and medicine transport with the purpose of more effective liver treatment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!